Assume independent radioactive detections with negligible dead-time loss, so accumulated counts have a Poisson distribution. The reference measurement has total count over . Since a Poisson count has variance equal to its mean, the rate uncertainty is
Its relative uncertainty is , or . For each one-second measurement, , giving the estimated count and rate uncertainties
in counts, numerically the same in counts per second for these one-second exposures. Their fractional uncertainties range from about at the first sheet to – for the smallest counts. The long, high-rate reference is therefore much more precise. These are statistical errors; a longer exposure does not automatically remove calibration errors, source drift or background bias.