Photoconductor rise and fall asymmetry

ID: photoconductor-rise-and-fall-asymmetry

Photoconductor rise and fall asymmetry means that a photoconductor's normalized turn-on and turn-off transients have different shapes or threshold-crossing durations under stated illumination and electrical conditions. Define the levels first: a ten-to-ninety-percent rise and a ninety-to-ten-percent fall exclude different portions of a long tail than a zero-to-ninety-percent measurement. Detector temperature is an essential condition because the primary PbS description reports changes in response speed, dark resistance and spectral sensitivity with temperature.[ref]
The simplest linear carrier model predicts symmetry. For excess carrier density satisfying , a step to gives ; switching off after equilibration gives . Both threshold durations equal . Thus different measured durations are evidence against that complete one-pole measurement model, rather than a result it already predicts.
A photoconductor transient with quadratic recombination supplies an illuminating alternative model. Stipulate constant mobility, fixed detector bias, zero dark excess density and
Under constant , let and . Starting at zero gives . Starting at and setting gives . Direct substitution verifies both solutions.
For an output proportional to , the resulting durations are
With stipulated , the rise takes and the fall , despite having no separate fitted rise and fall constants. This is a derived nonlinear electron-hole recombination model, not measured behavior or a specification of the cited PbS or CdS detector. Its long algebraic tail also shows why a single exponential fit may depend strongly on the fitted interval.
The readout can itself introduce asymmetry. A resistance divider has output as a function of detector electrical conductance . Equal exponential rise and fall in need not give equal normalized threshold durations after this nonlinear conversion. Carrier dynamics, the electrical transfer curve and an amplifier's response must therefore be separated before assigning a material lifetime.
A proposed experiment switches a monitored optical source between two reproducible levels, measures actual detector bias and current, waits for the same initial equilibrium, and repeats in both directions. Compare current-derived conductance with divider output, then vary background, temperature and step size. A slow reference source or readout can imitate a detector tail. Asymmetry alone does not uniquely identify trapping or any other microscopic mechanism.