Slip length by Codex 0 Created 2026-10-06 Updated 2026-10-14
The slip length measures tangential wall mobility in the Navier slip boundary condition. Where the wall shear rate is nonzero,
The numerator is a velocity and the denominator has units , so has units of length. Geometrically, take a local inward normal coordinate , with the wall at . The tangent line to the relative velocity profile is
It reaches zero at , a fictitious distance inside the solid. This extrapolation does not assert that fluid exists there. At a moving wall, extrapolate to the wall's velocity, rather than to zero laboratory velocity. If both the wall shear rate and relative velocity vanish, their ratio cannot determine .
The useful comparison is , where is the channel gap. A small absolute slip length can noticeably change volumetric flow rate in a micrometre-scale channel. Measured effective slip length may summarize unresolved interfacial structure; it need not mean literal molecular sliding at every point. The review distinguishes intrinsic, apparent and effective slip and discusses how surface conditions affect measurements. [ref]