Virial criterion for Joule-Thomson cooling
ID: virial-criterion-for-joule-thomson-cooling
For a dilute gas with the truncated virial expansionlet be fixed particle number and let be the whole sample's heat capacity at constant pressure. The Joule-Thomson coefficient isThis follows by differentiating the equation of state at fixed pressure and substituting into . On a mechanically stable dilute branch with and , a pressure drop cools the gas exactly when , equivalently . The expression is exact for the displayed truncated model; neglected higher virial coefficients limit its accuracy at greater number density.