David J. Craig 2026-11-05
David J. Craig is the credited writer of Boston University's 14 November 2003 account of research connecting dynamical systems, biology and biomedical engineering. His article describes James J. Collins's work on noise and sensation, including vibrating gel insoles intended to improve the detection of weak pressure signals from the feet. This is a contribution to communicating the research; the article attributes the experimental work to the researchers.[ref]
Dynamic solutions to physiological problems by David J. Craig. Byline, date and “Touch sensitive” section
The scientific puzzle in that account is stochastic resonance: under suitable conditions, adding noise can improve the detection of a weak signal. A simple explanatory model is a detector that responds when , where is the signal, the noise and a threshold. If , a detector without noise never responds; a fluctuating gives a nonzero probability of crossing the threshold. The same noise can also produce a response when the signal is absent, so an increase in threshold crossings alone does not establish improved discrimination. Craig's account places this counterintuitive mechanism in the concrete setting of mechanical stimulation of the sole rather than claiming that noise always helps.[ref]
Dynamic solutions to physiological problems by David J. Craig. “Touch sensitive”: weak-signal detection and the vibrating gel insole
Tissue engineering 2026-11-05
Tissue engineering uses biological cells, engineered environments and material structures to build or restore tissue-like function. A construct must do more than resemble the shape of a tissue: its cells need suitable surroundings, and the resulting structure must perform the intended biological or mechanical task. The field lies within biomedical engineering, whose scope includes engineering methods applied to biological materials and systems.[ref]
One approach seeds cells onto a tissue-engineering scaffold that provides an initial geometry and attachment environment. The cells can deposit extracellular matrix while the construct is maintained under controlled culture conditions. A bioreactor can supply nutrients and impose a defined mechanical environment. These roles should be distinguished: a scaffold’s initial strength, the matrix produced by the cells and the mature construct’s function need not be identical.
A motivating primary experiment is the 1999 report of arteries grown from vascular smooth muscle cells and endothelial cells. Bovine vessels were cultured under pulsatile conditions, then assessed for rupture strength, suture retention, contraction and cellular differentiation. The study also reported implantation in miniature swine, with a finite follow-up observation. The combination of mechanical and biological measurements illustrates why a tissue-like shape alone is insufficient evidence of function.[ref]
Functional arteries grown in vitro by L. E. Niklason and others. Primary abstract: cell sources, pulsatile culture, functional measurements and animal implantation
A simple design calculation shows how size affects cell support. For diffusion with characteristic diffusivity , the diffusion time over distance scales asFor illustrative , a distance gives , whereas gives . The tenfold increase in distance produces a hundredfold time scale. These chosen values do not establish a survival limit: consumption, binding, boundary concentrations and fluid transport also matter. They explain why scaling up a dense construct introduces a transport problem, rather than merely requiring more cells.
The engineering task is to coordinate transport, cell adhesion, matrix formation, biocompatibility and mechanical demands. An experiment can measure each separately: nutrient conditions, viable-cell distribution, matrix organization and force response. Together those observations test whether the designed environment has produced the intended tissue function.