Coronary oxygen delivery is the rate at which oxygen is brought to a specified myocardial territory in its arterial blood supply. If volume flow is and arterial oxygen content is , then
Flow and content must use compatible volume units and refer to the same territory and interval. Delivery is an inflow quantity; coronary oxygen uptake is the net amount removed from the blood by the represented tissue.
For an original example, and give . The same delivery can arise from with , or with : both give . Delivery alone cannot identify which factor changed.
Oxygen content is not the same observable as oxygen partial pressure or oxygen saturation. Much of blood's oxygen is carried by hemoglobin; the amount of carrier therefore matters as well as its saturation.[ref] Substituting a pressure value for would also fail dimensionally.
An original independent-error approximation gives
Relative standard uncertainties and combine to about under the stated assumptions. A covariance term is required when the input errors are correlated.[ref]
The measurement apparatus determines which input is actually observed. A primary coronary-flow study used continuous saline infusion and a pressure/temperature-sensing guidewire, testing volumetric flow estimation in five dogs and 35 patients.[ref] Such a temperature-dilution observation does not itself measure oxygen content; a delivery estimate must obtain that input separately.
Mass-specific myocardial oxygen delivery adds a tissue-mass denominator. Total delivery to corresponds to per . A bulk value, a mass-normalized value and a regional value answer different questions, and normalizing a total does not reveal uneven distribution within the territory.
Mass-specific myocardial oxygen delivery expresses oxygen inflow relative to the mass of the represented myocardial tissue. If total coronary oxygen delivery is to mass , the per-mass quantity is . Reporting per gives
The mass and inflow must refer to compatible territories. Normalizing a branch flow by an unrelated whole-heart mass changes the quantity rather than simply changing its units.
An original example has two regions: receiving , and also receiving . Their mass-specific deliveries are and per . The combined value is
It is the mass-weighted mean , not the unweighted mean . Equal total inflows do not imply equal delivery per tissue mass.
Normalization does not remove measurement uncertainty. For small independent input errors,
Relative uncertainties in delivery and in mass combine to about . With correlated errors, the relative covariance term must also be included.[ref]
An experimental flow measurement still needs separate oxygen-content and mass information. The primary coronary thermodilution apparatus estimated volumetric flow in a selected artery using infusion and temperature sensing.[ref] A mass-normalized oxygen-delivery estimate therefore combines several observations and a territory model.
Finally, a regional mean can conceal spatial variation. Two regions can share the same average per-mass delivery while distributing flow differently within them. The denominator makes comparisons explicit; it does not establish uniform perfusion or equal coronary oxygen uptake.

Articles by others on the same topic (0)

There are currently no matching articles.