An exact teaching model makes the peak suppression explicit. Assume the narrowband field correlation separates as after delay compensation. Average each channel's light intensity over the same rectangular gate of duration . The two time integrals have triangular relative-delay weight
Integrating the Siegert relation against this weight gives
The factor is one for a selected polarization of waves and for two independent equally populated polarizations. The signal fraction uses mean stellar signal and independent additive background in each detector. The photon correlation loss and background model then supplies . This assumes no correlated sky background or electronic coupling.
For the original model , elementary integration gives
The area-based optical coherence time of this intensity envelope is . For , ; for , . With the chosen , , , and , and . At the stipulated disk gives approximately . A nearly unit measured can therefore conceal a substantial .
This rectangular-gate calculation specifies a counting model. An analog instrument's amplifier bandwidth and impulse response instead weight the fluctuations it actually passes; the Sirius amplifiers were bandpass devices. Both require measuring the response and calibrating the zero-baseline excess. When , , and the temporal response are unchanged, the ratio of excesses recovers :
A sufficiently unresolved calibration source can supply the denominator; dividing the full values would give the wrong result. Narrower optical bandwidth lengthens optical coherence time, whereas wider usable electronic bandwidth can resolve faster fluctuations; these are distinct bandwidths. Background changes, unequal spectral responses, drift, or averaging over changing interferometric baselines can invalidate a common calibration. Resolving a disk means establishing a reproducible decline of calibrated correlation, supported by those controls.

Articles by others on the same topic (0)