Gouy phase 2026-11-05
The Gouy phase describes the additional axial phase associated with a focused wave relative to a plane wave. For a fundamental circular Gaussian beam with beam waist at and Rayleigh range , defineWith the carrier convention , the on-axis field phase is up to a constant. Thus the signed additional phase is in this convention; defining the positive function does not reverse the physical prediction.[ref]
Physical origin of the Gouy phase shift by Simin Feng and Herbert G. Winful. Equation12, printed p.486, sign convention for the Gaussian phase contribution
The complex field prefactor gives a short derivation. The normalized Gaussian propagation factor isIts modulus describes the on-axis amplitude reduction; its argument is the additional phase. An intensity measurement alone loses this argument, so measuring the beam's width and brightness does not directly measure the Gouy phase.
As runs from far before to far after the waist, runs continuously from to . The total additional phase change has magnitude , but is not a discontinuous jump at the waist. For stipulated and , . Between and , the additional phase changes by ; the far-field-to-far-field limit gives .
The number of confined transverse directions matters. A Gaussian beam with one transverse coordinate has prefactor and half this phase contribution. Simin Feng and Herbert G. Winful's primary analysis relates the effect to transverse confinement and the angular spectrum representation: a localized beam includes transverse wave-vector components, affecting axial propagation.[ref]
Physical origin of the Gouy phase shift by Simin Feng and Herbert G. Winful. Equations4–12 and line-focus versus point-focus discussion, pp.485–486
An illustrative Gouy phase interferometry experiment overlaps the focused beam with a coherent reference beam and records the interference phase at different axial planes. Removing the ordinary optical-path contribution and accounting for wavefront curvature isolates the axial phase change. This is a proposed measurement outline, not an experimental result reported by the cited theoretical paper. In an optical cavity, related phase contributions help determine the resonance condition and distinguish transverse modes.
Herbert G. Winful 2026-11-05
Herbert G. Winful is an electrical-engineering researcher at the University of Michigan whose work includes nonlinear optics and photonics. His institutional record and the full byline of his 2001 paper with Simin Feng verify this identity.[ref]
Herbert Winful profile at the University of Michigan. Official faculty research-interest record
[ref]Physical origin of the Gouy phase shift by Simin Feng and Herbert G. Winful. Printed p.485, full bylines and affiliation
Their primary analysis relates the Gouy phase of a focused wave to transverse confinement and the distribution of transverse wave vectors. It accounts for the different phase contributions in line and point focusing, rather than relying on a geometrical explanation restricted to one focusing geometry.[ref]
Physical origin of the Gouy phase shift by Simin Feng and Herbert G. Winful. Equations4–12 and the one- versus two-transverse-dimension discussion, pp.485–486
A constructed interference example shows why a phase contribution is measurable even when the separate beam powers are unchanged. Let two mutually coherent beams each contribute light intensity at a detector. If their fields have relative phase , their combined intensity isA relative phase change from zero to changes the combined intensity from to zero at that location. Each beam alone still contributes . This is an ideal local interference calculation, not a reported experimental result from the theoretical paper; spatial overlap and polarization must also permit interference.
Gouy phase interferometry uses this phase sensitivity while separating the focusing contribution from ordinary optical-path changes and wavefront curvature. The scientific distinction is between a measured intensity pattern and the phase information inferred using a specified field model. The paper's relevance to optical cavities likewise comes from phase matching, rather than from beam width alone.