National Instruments, LabVIEW Analysis Concepts, March 2004 edition, part 370192C-01. Printed pages 5-20–5-24 distinguish periodic spectral windows from symmetric filter-design windows and discuss coherent-gain amplitude scaling, equivalent noise bandwidth and off-bin amplitude errors. Table 5-3 gives Hanning coherent gain 0.50 and ENBW 1.50.