Allan M. Maxam 2026-11-05
Allan M. Maxam, with Walter Gilbert, developed a chemical approach to DNA sequencing reported in 1977. Their primary paper describes partial cleavage of terminally labeled DNA at selected bases, then size separation of labeled fragments by polyacrylamide gel electrophoresis.[ref]
A new method for sequencing DNA by Allan M. Maxam and Walter Gilbert. PNAS 74, pp. 560–564, original full byline and Abstract
Maxam-Gilbert sequencing converts chemical selectivity into a position-dependent pattern along a pre-existing strand.The word partial is central to the measurement logic. Different molecules contribute fragments ending at different positions, while a common labeled end supplies a reference. Extensive repeated cleavage of one molecule can remove information about more distant sites, because only the fragment still containing the label is visible in the corresponding readout.
An original probability model illustrates the tradeoff without prescribing experimental conditions. Suppose the number of relevant breaks in one molecule follows a Poisson distribution with mean . ThenAt stipulated , about 81.9 percent have no break, 16.4 percent have one and 1.75 percent have multiple breaks. At , those fractions are about 13.5, 27.1 and 59.4 percent. More cleavage does not translate monotonically into a more interpretable set of singly terminated fragments. Actual sequence-dependent chemistry need not follow this simplified independent-break model.
The measured gel is also not the sequence itself. Reading requires calibrating fragment size, identifying the labeled end and comparing the base-selective channels. Overlapping bands or an incorrect orientation can corrupt an otherwise real chemical signal. Maxam's contribution demonstrates how a carefully designed molecular measurement can expose sequence information that bulk composition alone cannot recover.
Walter Gilbert 2026-11-05
Walter Gilbert helped turn questions about gene regulation and DNA sequence into experimentally accessible molecular measurements. He moved from physics toward molecular biology at Harvard; the Cold Spring Harbor Laboratory archive records that transition and preserves his research collection.[ref]
Walter Gilbert in the Cold Spring Harbor Laboratory archives. Institutional biography and Scope and Content
Walter Gilbert, portrait identified by Cold Spring Harbor Laboratory and credited to Harvard News Service
. Source. With Benno Müller-Hill, Gilbert reported isolation of the lac repressor in 1966. Their assay detected binding to an inducing small molecule using equilibrium dialysis, providing a biochemical handle on a genetically inferred control protein.[ref]
Isolation of the lac repressor by Walter Gilbert and Benno Müller-Hill. printed p. 1891, assay description
The distinction between a measurable binding activity and a fully established regulatory mechanism remains important: the assay did not assume that every detail of operator recognition was already known.With Allan M. Maxam, he later developed the chemical DNA sequencing method now called Maxam-Gilbert sequencing. Their 1977 paper described partial cleavage at selected bases in terminally labeled DNA, followed by polyacrylamide gel electrophoresis to resolve fragment lengths.[ref]
A new method for sequencing DNA by Allan M. Maxam and Walter Gilbert. PNAS 74, pp. 560–564, Abstract
A ladder of labeled fragment lengths converts chemical specificity into information about positions along a strand.An original schematic inference illustrates the readout. Suppose calibrated fragment-length patterns assign A to positions 1 and 6, G to positions 2 and 5, C to positions 3 and 7, and T to positions 4 and 8. Combining the position sets gives AGCTGACT in the stated reading direction. A G-selective measurement alone would leave six positions unresolved; the different chemical channels supply complementary information.
The example abstracts away migration calibration, cleavage-site offsets and band overlap. Real interpretation requires identifying the labeled end and relating each band to the appropriate base position. This sequencing approach interrogates a pre-existing labeled strand through cleavage, so its measurement logic is different from inferring sequence from terminated synthesis products. Gilbert's work exemplifies how designing a recoverable physical signal can transform an otherwise indirect molecular question.