Astronomical interferometer Created 2026-10-18 Updated 2026-11-05
An astronomical interferometer combines observations from separated collecting locations to infer angular source structure. Its projected interferometric baseline determines the angular spatial frequency sampled. Amplitude and intensity interferometers measure different coherence observables; a Michelson stellar interferometer combines optical field amplitudes.
Michelson stellar interferometer Created 2026-10-18 Updated 2026-10-20
The Michelson stellar interferometer, associated with Albert Abraham Michelson, uses separated collectors and beam-redirection optics to produce interference fringes. The collector spacing determines sensitivity to a stellar angular diameter, independently of the final beam spacing at the combiner. The first null for a uniform disk is , where is the full angular diameter. Different surface-brightness laws, including limb darkening, change the null.
Temporal coherence compares the field at different times at one location: a narrow spectrum maintains a predictable phase relation over a longer delay. Spatial coherence compares the field at different locations at the same time: different angular source components illuminate a baseline with different phase differences, which wash out interference when averaged. These are properties of correlations, not claims that all thermal source points have a common phase.
Assume a distant spatially incoherent, quasimonochromatic source, small angles, identical slit transmission, matched polarizations and equal mean intensity at the two slits. For an angular component , the relative input phase is . Let be the additional observation-plane phase. Incoherent angular components add intensities, givingIts extrema are , henceFor symmetric , is a real cosine transform. Physical visibility is its normalized absolute value; the printed proportionality omits that qualification. A negative signed coherence reverses fringe phase rather than giving negative contrast. This is the small-angle Van Cittert-Zernike theorem. Temporal coherence analogously depends on the Fourier transform of the spectrum.
A Michelson stellar interferometer uses separated collecting mirrors to obtain a large adjustable projected baseline without requiring a monolithic objective of that diameter. Each collector supplies light to a common combiner. Optical path compensation keeps the delay within the temporal coherence range; varying mirror separation samples spatial coherence and resolves stellar angular structure finer than a small collector alone.
Let be the normalized signed coherence of one star, and take the baseline along the projected binary separation. The equal-brightness binary-star visibility for identical profiles centred at giveFor uniform circular discs of angular diameter ,For binary separation from visibility-zero spacing, the rapid binary visibility zeros satisfy , so their repeated spacing is . The slower single-star envelope first vanishes at . The stellar angular diameter from a visibility envelope and the binary separation follow by fitting both scales; multiple baselines distinguish envelope zeros from binary zeros.
Original normalized binary-star visibility sketch for two uniform circular discs, with projected separation eight times their diameter; binary zeros and the stellar-diameter envelope are labelled
. Details. Angular width alone does not specify a unique brightness profile. If the intended one-dimensional model is a uniform angular strip of full width , replace the disc factor by with ; its first envelope zero is . Limb darkening changes the disc envelope too. Rotating the baseline is necessary to recover an unknown separation direction; a single orientation measures only its projection.
Each mutually incoherent patch of an extended star produces a displaced double-slit interference pattern. The detector adds their light intensities. For two apertures separated by a projected interferometric baseline , a source direction offset by a small angle changes their phase difference by . The normalized sum over the source's angular brightness distribution is its first-order optical coherence, whose magnitude is the interferometric visibility for equally bright channels.
For a uniform circular stellar disk of full angular diameter , the normalized angular Fourier transform gives the uniform-disk stellar visibilityHere is the order-one Bessel function of the first kind. This follows by integrating over the disk and dividing by its area. In particular, its power series gives .
For an ordinary slit separation , using the paper's and observing wavelength ,Even gives a visibility loss of only . Thus millimetre separation leaves the interference fringes almost indistinguishable from those of a point source; it gives very little sensitivity to the diameter.
The movable mirrors in the Michelson stellar interferometer collect light at a large adjustable separation and redirect it into closely spaced output beams. They increase the sampling interferometric baseline independently of the fixed output slit spacing : sets sensitivity to source structure, whereas the output optics set the screen's interference fringe spacing. The first Bessel function zero is , henceThe interference fringes disappear at this baseline even though each beam separately remains bright.
The value assumes a uniform disk. The original question supplies a diameter without a surface brightness law; real limb darkening changes the precise visibility zero. A one-dimensional uniformly bright strip of the same full angular width instead has a sinc function visibility and first zero . That is a different source model, not the circular-disk result. The robust conclusion without a surface brightness model is that a baseline of a few metres, rather than millimetres, is required.