An astronomical interferometer combines observations from separated collecting locations to infer angular source structure. Its projected interferometric baseline determines the angular spatial frequency sampled. Amplitude and intensity interferometers measure different coherence observables; a Michelson stellar interferometer combines optical field amplitudes.
The Michelson stellar interferometer, associated with Albert Abraham Michelson, uses separated collectors and beam-redirection optics to produce interference fringes. The collector spacing determines sensitivity to a stellar angular diameter, independently of the final beam spacing at the combiner. The first null for a uniform disk is , where is the full angular diameter. Different surface-brightness laws, including limb darkening, change the null.
Each mutually incoherent patch of an extended star produces a displaced double-slit interference pattern. The detector adds their light intensities. For two apertures separated by a projected interferometric baseline , a source direction offset by a small angle changes their phase difference by . The normalized sum over the source's angular brightness distribution is its first-order optical coherence, whose magnitude is the interferometric visibility for equally bright channels.
For a uniform circular stellar disk of full angular diameter , the normalized angular Fourier transform gives the uniform-disk stellar visibility
Here is the order-one Bessel function of the first kind. This follows by integrating over the disk and dividing by its area. In particular, its power series gives .
For an ordinary slit separation , using the paper's and observing wavelength ,
Even gives a visibility loss of only . Thus millimetre separation leaves the interference fringes almost indistinguishable from those of a point source; it gives very little sensitivity to the diameter.
The movable mirrors in the Michelson stellar interferometer collect light at a large adjustable separation and redirect it into closely spaced output beams. They increase the sampling interferometric baseline independently of the fixed output slit spacing : sets sensitivity to source structure, whereas the output optics set the screen's interference fringe spacing. The first Bessel function zero is , hence
The interference fringes disappear at this baseline even though each beam separately remains bright.
Figure 1.
Original calculated interferometric visibility for the given stellar diameter and wavelength
. Details.
The value assumes a uniform disk. The original question supplies a diameter without a surface brightness law; real limb darkening changes the precise visibility zero. A one-dimensional uniformly bright strip of the same full angular width instead has a sinc function visibility and first zero . That is a different source model, not the circular-disk result. The robust conclusion without a surface brightness model is that a baseline of a few metres, rather than millimetres, is required.