Mike Beckman is an electrical engineer identified in a 2013 Texas Instruments reference design as a systems engineer who, at that time, managed its converter product line. With Luis Chioye, he coauthored Precision Thermocouple Measurement with the ADS1118 by Mike Beckman and Luis Chioye, combining an analog-to-digital converter, thermocouple input and on-chip temperature sensor.[ref]
Precision Thermocouple Measurement with the ADS1118 by Mike Beckman and Luis Chioye. Title page and §9, printed p. 23, authors and contemporary engineering roles
Their design treats cold-junction compensation as both an electrical calculation and a thermal-layout problem. It places the converter near the connector and uses copper regions to improve cold-junction thermal coupling, while separating nearby heat sources. Its tests distinguish changing the reference-junction temperature from changing the measuring-junction temperature.[ref]
Precision Thermocouple Measurement with the ADS1118 by Mike Beckman and Luis Chioye. §4, printed p. 15, Figure 11; §7, printed pp. 20–21
A simple original linear model illustrates the reason. If a thermocouple has stipulated sensitivity and measures , then implies . A reference junction at therefore gives . Reading that junction as instead gives , despite perfect measurement of . The model uses constant sensitivity only for illustration; actual cold-junction compensation uses the appropriate thermoelectric conversion.
Articles by others on the same topic