Murray's law predicts for an ideal blood vessel whose radius balances pumping power against the cost of maintaining its blood volume. Cecil D. Murray formulated this minimum-cost model in 1926. [ref]
Consider a cylindrical segment of fixed length , prescribed positive volumetric flow rate and constant dynamic viscosity . The Hagen-Poiseuille equation gives pumping power . Adding a maintenance cost per unit volume per unit time gives
Differentiation gives
The pumping term diverges as , while the maintenance term diverges as ; the unique stationary radius is the minimum.
At an ideal bifurcation, conservation of mass for an incompressible flow gives . If the three segments have the same and , their common proportionality constant cancels:
Equal daughters therefore have , approximately . This prediction depends on the model: pulsatile inertia, differing maintenance costs and radius-dependent apparent viscosity, including the Fahraeus--Lindqvist effect, can change the optimum.