The printed line-density statement is incorrect for a phase-mixed orbit. A steady line density on a Kepler orbit is inversely proportional to speed: for a cross-sectional-area current , the area per unit arc length is . Equivalently, phase mixing gives , uniform in mean anomaly, where is the orbital period.
For an optically thin population of blackbodies in radiative equilibrium, a fragment absorbs and reradiates the same luminosity. Thus the fractional luminosity of a phase-mixed eccentric wire is
The specific angular momentum gives , so the integral is . Since ,
This derives the intended result after explicitly correcting the density to .
The error is consequential. If one instead imposes the literal density , its time weighting is . Using , and gives
At this is times the printed result. The inverse-radius averages can also be obtained directly with eccentric anomaly , and .