An immersion liquid increases numerical aperture through , if the optics can use the same ray angle inside a transparent, chemically compatible liquid of refractive index . With unchanged and vacuum wavelength, the width scales as at fixed angle. If the two empirical formulae printed in the question are used literally with fixed , they give .
For a physical axial displacement inside the medium, however, the familiar paraxial defocus range contains an additional index factor: . That convention gives at fixed ray angle, or an approximately -fold larger depth of focus at fixed and resolution. Thus immersion can improve lateral resolution, while its focus benefit depends on what is held fixed and on the axial-focus convention. It cannot improve resolution merely by inserting into while ignoring optical redesign, absorption or resist compatibility. No liquid index is supplied for a numerical prediction.