Photoisomerization is a light-induced conversion between molecular isomers: absorption of a photon initiates a change in molecular arrangement without requiring a change in elemental composition. The resulting isomers can have different shapes, spectra or interactions even though they contain the same kinds and numbers of atoms.
A biological example occurs in rhodopsin. Its bound 11-cis-retinal chromophore changes toward all-trans-retinal after light absorption, initiating changes in the receptor that can activate transducin. This converts a molecular rearrangement into a signaling event.[ref]
The change is an example of cis-trans isomerism, not fragmentation of retinal into smaller molecules. “Light-induced” also does not mean that every photon entering a sample produces one permanent isomerization. Absorption, competing excited-state processes and subsequent reactions can affect the measured outcome.
An idealized photochemical quantum yield for a specified primary product is . If 100 photons are absorbed and 30 product-forming events are counted under a defined low-conversion assay, . Counting incident rather than absorbed photons would answer a different question. The example is bookkeeping, not a measured rhodopsin yield.
The surrounding protein can influence the chromophore's behavior by controlling its local environment. A free molecule's light response therefore need not be identical to its behavior inside a receptor. The useful mechanism is the full chain from absorption to rearrangement to altered interaction with other molecules.
The photochemical quantum yield measures the number of specified chemical events per excitation photon absorbed by the system. For an integrated product measurement,
Counts or amounts of substance must be used consistently. State the product or reactant-change event, excitation wavelength and experimental conditions. A wavelength-specific yield strictly refers to monochromatic excitation.[ref]
Absorbed and incident light are different denominators. Under the simple transmission model, the fraction absorbed at absorbance is . If of photons arrive at a sample with , then are absorbed, neglecting reflection and scattering. Formation of of the chosen product gives ; dividing by incident exposure instead gives . These are invented bookkeeping values, not a measured reaction yield.[ref]
A measurement therefore combines two calibrations: quantify the chemical change and determine absorbed photon exposure. A differential yield uses the reaction rate divided by absorbed photon flux; an integrated yield averages the specified change over an exposure. Changing absorption as products accumulate can make those quantities differ.
Photoisomerization supplies one application, but the definition requires the chosen event rather than an assumption that every absorbed photon makes one permanent product. A yield for chemical conversion also differs from a fluorescence quantum yield, which counts emitted photons. The numerical example does not impose a universal upper bound on every possible definition of a photochemical event.
Absorbed photon flux is the rate at which a specified sample absorbs photons. Number-based flux counts photons per second; amount-based flux counts moles of photons per second. The absorbed rate differs from the incident rate and supplies the denominator of a rate-based photochemical quantum yield. For monochromatic light passing through a homogeneous absorbing sample,
where is incident photon flux and is the decadic absorbance at the excitation wavelength. Reflection and scattering must be absent or accounted for before transmission loss is interpreted entirely as absorption.[ref]
For example, and give
A product-formation rate of would then give photochemical quantum yield approximately , whereas division by incident flux gives . The two calculations answer different questions.
The distinction also matters during an experiment: if absorbance changes as a reactant is consumed, one initial flux value cannot represent the whole exposure. Absorbed photon amount is the time integral of the absorbed rate. If the numerator is a change of concentration per second, divide the total absorbed amount rate by the illuminated sample volume as well. A photon rate, a rate per unit area and a rate per unit volume have different dimensions; the word flux alone should not conceal that distinction.[ref]

Articles by others on the same topic (0)

There are currently no matching articles.