The regurgitant fraction is the proportion of a valve-related total ejected blood volume that returns through the leaking valve. For the left ventricular balance used to assess mitral regurgitation, let be total ventricular stroke volume, the matched forward aortic volume and the regurgitant volume. With no other abnormal communication or confounding valve leak,
The imaging recommendations use complementary volume and flow measurements to quantify these quantities.[ref]
An original example takes mL and mL. Then mL and RF is 30%. The quotient instead expresses leakage relative to forward delivery; it is not the same fraction. The denominator is part of the definition.
Equal fractions also need not indicate equal transported amounts. A 30 mL leak out of 100 mL and a 60 mL leak out of 200 mL both have RF 30%. Conversely, an unchanged 30 mL regurgitant volume gives RF 50% if total ejection falls to 60 mL. These stipulated cases isolate the normalization rather than assigning a clinical severity category.
The two measurements in a derived RF may share errors. For , first-order propagation gives
The covariance term should follow the actual acquisition and data reduction, rather than assuming independence because forward and total volume have different names.[ref]
RF is therefore a normalized transport quantity. A peak jet velocity, a valve image and ejection fraction provide other information; none supplies RF without the matching flow or volume model. Specify the valve, flow convention and acquisition interval when comparing measurements.