A coverage-preserving detector-width bound from a variance interval transforms uncertainty in a nonnegative response variance without imposing a symmetric width error bar. Let and let a random interval have stated frequentist coverage for . Define the width confidence set byFor the true width ,The events are identical, so their coverage probabilities are identical. The transformation does not create coverage that the original interval lacked. Resolution-limit conditioning in finite-input detector calibration explains why working with the variance difference first is useful near a barely resolved detector response.
For an original explicit measurement model, suppose has a normal distribution with mean and known standard deviation . A reading gives an approximately 95 percent interval . Intersecting with the physical range and taking square roots gives . This is an assumed normal model for measuring , not a claim that any difference of fitted squared widths is automatically normal.
If the entire variance interval is negative, the result is an empty physical confidence set for a detector variance difference. Do not replace its negative upper endpoint by zero and report an apparently exact zero width: that changes the confidence-set construction. An empty realization signals disagreement between that interval and the physical parameter range; it can occur even in a valid procedure on an occasional sample that misses the true value.
NIST distinguishes a standard uncertainty from an interval with a justified confidence level and explains the distributional assumptions behind a coverage factor near two.[ref]
Guidelines for Evaluating and Expressing the Uncertainty of NIST Measurement Results by Barry N. Taylor and Chris E. Kuyatt. §§6.2–6.3, Expanded Uncertainty
The normal interval above needs its stated model; the monotone transformation proof itself does not. Application to a detector additionally requires the nonnegative-profile convolution assumptions of finite-input correction in pulse-detector calibration; a correct statistical transformation cannot repair an invalid physical variance identity.Finite-input correction in pulse-detector calibration removes the known input duration from an inferred receiver width, while propagating uncertainty in both widths. Under the nonnegative, normalized, finite-variance convolution model of known-input calibration of a pulse detector,where is the known input profile, the measured output and the receiver's impulse response. The subtraction concerns temporal variances, not arbitrary reported full widths.
Differentiating on the positive-width branch givesFirst-order propagation of standard uncertainty therefore yieldsThe covariance matters when both widths use the same timebase or fitted reference.[ref]
An original near-resolution example has and , each with independent standard uncertainty . The corrected receiver width is and its propagated standard uncertainty is about , or . Width measurements individually precise to about one percent can thus give a much less precise difference-derived width.
NIST's primary bandwidth-correction procedure used roughly 120 ps optical inputs and recorded the detector, cable and oscilloscope as one response chain at different gains and signal levels.[ref]
Calibration Service for Low-level Pulsed-Laser Radiometers at 1.06 µm: Pulse Energy and Peak Power by Rodney W. Leonhardt. Appendix C.1–C.2, printed pp. 36–37, Figure C1 and steps 1–7
A sufficiently short characterized input reduces this resolution-limit conditioning in finite-input detector calibration. Near a zero variance difference, linear uncertainty propagation may fail; a nonpositive measured difference does not represent a negative physical detector width. Report an interval or limit under the stated model rather than silently replacing the difference by zero. Negative ringing also violates the nonnegative-profile assumption behind the variance subtraction.