A polymer fraction-recovery balance accounts for material recovered in each sampled fraction after a polymer experiment, including retained solids, dissolved products, filter deposits and container rinses. It tests whether the fractions used to infer a molar mass distribution represent the intended population. A decrease in retained mass and a change in the number-average molar mass of the analyzed fraction are different observations.
First specify a polymer recovery accounting basis. Comparable dry masses can be summed when they describe the same material inventory; chemical transformation may instead require a conserved-element or repeat-unit inventory. For example, ester hydrolysis incorporates water into new end groups. Summing product mass as though it were unchanged original polymer mass then mixes accounting conventions. The manufacturer's decomposition diagram for polyglycolic acid explicitly distinguishes hydrolytic decomposition from later microbial degradation.[ref]
For an original closed repeat-unit bookkeeping model with no destruction of those units, let be the initial inventory. Write
Here is recovery on that specified basis. Material converted into unmeasured chemical products belongs in the unaccounted inventory until measured; a recovery deficit alone does not identify its chemical fate.
On a stipulated consistent mass-equivalent basis, start with 100 mg and recover 70 mg in solids, 20 mg in the soluble fraction and 5 mg in rinses. Recovery is 95%, leaving 5 mg unaccounted. The 30 mg decrease in retained solids is not evidence that all 30 mg was collected as soluble material: only 20 mg was measured there. Experimental mass balance requires those distinctions even when a single residue curve appears smooth.
Combining recovered number-average molar masses also requires counting chains rather than averaging the reported means by mass. If fraction has mass and correctly measured number-average molar mass , its amount of substance of chains is . Thus, for the combined measured fractions,
An original example recovers 80 mg with and 20 mg with . These correspond to and of chains. Their combined 100 mg divided by gives . The mass-weighted average of the two reported means, , is not their combined number-average molar mass. Missing fractions with unknown chain counts prevent this calculation from establishing the whole original population's mean.
A useful collection protocol measures initial material, retained residue, filtrate and rinses separately, with preparation blanks and stated drying conditions. Kureha's published water-exposure protocol measures filtered, dried solids, so that observable covers only one part of the balance.[ref] A size-exclusion chromatography trace of a selected fraction adds another measurement model: IUPAC defines that separation chiefly through hydrodynamic volume in porous non-adsorbing material.[ref] Recovery, representativeness and the conversion from separation to molar mass must all be justified before interpreting a survivor distribution as the full degraded sample.
Selective-fragment-loss bias in polymer molar mass arises when the chains retained or analyzed are not representative of the original molecular population. Preferential loss of short fragments can raise the measured number-average molar mass of the survivors even while the specimen loses mass and chain scission continues.
Let denote molar mass for a molecule drawn with equal probability from the original chain population. If its retention probability is , the number-average molar mass of retained chains is
Consequently
Retention favouring larger chains can make this difference positive. This is an original selection calculation; it does not assume a particular hydrolysis mechanism. If the intended measurand is explicitly the retained fraction, its correctly measured mean is not intrinsically erroneous. Bias appears when that mean is interpreted as the whole population's mean.
An original mixture has 90 chains at and ten at . Its number-average molar mass is . Removing all short chains leaves the survivor mean at 100, although only of the initial chain mass has left. The large numerical increase does not imply chain growth.
A weight-average molar mass is a different statistic: . The same initial mixture has , showing why an averaging convention must accompany a reported molecular-mass value. Equal molecule weighting and equal mass weighting answer different questions.
Experimentally, distinguish residue, released soluble fragments and the fraction actually injected into the analytical instrument. A polymer fraction-recovery balance can compare their recovered mass. The manufacturer's polyglycolic acid test measures filtered dry residue after water exposure; it does not directly supply the chain distribution in the liquid that passed through.[ref]
Size-exclusion chromatography adds a further measurement model: IUPAC defines its separation chiefly through hydrodynamic volume in a porous, non-adsorbing material, not molecular mass alone.[ref] Solubility, preparation losses, detector response and the mass calibration can therefore affect what distribution is inferred. Preserve the sampled fraction's identity instead of treating a cleaner chromatogram or a higher surviving mean as evidence that degradation reversed.