Common-mode support interference in mounting comparisons is an aerodynamic disturbance shared by different mounting arrangements, so that agreement between their corrected loads fails to reveal it. Repeating a wind tunnel measurement with several supports can test differences in support effects without identifying their shared absolute contribution.
Write the support-tare-corrected load for mount aswhere is the desired isolated-model force, a shared wind-tunnel support interaction residual, a mount-specific residual and measurement noise. Differences eliminate both and :Even arbitrarily precise agreement does not separate from . Replacing by leaves every predicted observation unchanged. This is shared-bias nonidentifiability in mounting comparisons.
For an original example, corrected mount results 21.9, 22.0 and 22.1 N are compatible with isolated-model force 20.0 N, common residual 2.0 N and mount-specific residuals N. Averaging reduces their visible spread but does not remove the common 2 N. A standard error derived only from replicate spread would omit that contribution.
An independent bound adds information. If a reference experiment justifies N and other residuals are negligible, an exact mean 22 N implies N. Without the independent bound, agreement alone supplies no such interval. The reference must constrain the common disturbance, rather than repeat the same unvalidated subtraction.
Real support interference altered both airfoil drag coefficients and their inferred thickness dependence in the 1939 variable-density-tunnel investigation.[ref]
Airfoil Section Data Obtained in the NACA Variable-Density Tunnel as Affected by Support Interference and Other Corrections by Eastman N. Jacobs and Ira H. Abbott. NTRS abstract, support-interference correction and airfoil-thickness trend
Multiple mounting arrangements are useful diagnostics, but their concordance establishes only the aspects to which the comparison is sensitive. Empty-tunnel support tare 2026-11-05
An empty-tunnel support tare is the wind-on aerodynamic load measured with the support arrangement present but the test model absent. Subtracting that load from the model-plus-support measurement removes a specified support contribution under matched conditions. It does not automatically remove the wind-tunnel support interaction residual created by their combination.
The word empty here means empty of the test model, not empty of its mounting hardware. A wind-off zero or orientation tare addresses other contributions, such as instrument offset or the changing component of gravitational weight. Neither measurement establishes the support's aerodynamic load in moving air.
An original scalar example uses model-plus-support force 12.00 N and matched support-only force 1.08 N. Their difference is 10.92 N. With air density , speed m/s and reference cross-sectional area , the dynamic pressure and load normalization areIf the channel is drag, the support tare corresponds to drag coefficient increment , and the corrected measured coefficient is . Those numbers describe the subtraction; they do not certify an isolated-model drag coefficient when interference remains.
At the same normalization, a 0.10 N tare error contributes about 0.00185 to the coefficient error. A tare measured at the wrong speed, orientation or support geometry can therefore matter even when the force offset appears small. Document conditions and propagate measurement uncertainty, rather than treating a stored tare as exact for every run.
The variable-density-tunnel support-interference investigation demonstrates why direct support load and interference require separate attention.[ref]
Airfoil Section Data Obtained in the NACA Variable-Density Tunnel as Affected by Support Interference and Other Corrections by Eastman N. Jacobs and Ira H. Abbott. NACA-TR-669, abstract: support interference changed drag data and airfoil-thickness trends
The arithmetic above is an original normalized-load example, not a reported tunnel result. Wind-tunnel model support correction 2026-11-05
A wind-tunnel model support correction estimates the aerodynamic contribution of a model's mounting system to measured forces and torques. It can include the support's direct load and the altered fluid flow produced when support and model are together. An empty-tunnel support tare addresses the first effect but need not identify the second.
For a single load channel, write the defined measurement model asHere is the desired isolated-model load, is the support-only load and is the wind-tunnel support interaction residual. The equations assume the same channel zero, conditions and support configuration, with other loads already removed. For stipulated values , and , simple tare subtraction reports , retaining a 10% bias relative to the desired load.
This limitation affected real design data. In their 1939 report, Eastman N. Jacobs and Ira H. Abbott found that support interference had made published airfoil drag coefficients too large and had exaggerated their increase with section thickness. Their correction therefore changed more than a single constant offset: it affected the inferred trend used to compare airfoil shapes.[ref]
A proposed diagnostic repeats measurements with altered supports or attachment positions while maintaining a common target condition. Dependence on the mounting arrangement demonstrates a setup sensitivity; extrapolating to an unmounted model requires a justified mathematical model, not merely averaging the mounts. Wind-off orientation tares, support-only wind-on loads and model–support interactions answer different questions. Record each separately and propagate its measurement uncertainty through the reported correction.