In a gas syringe, the graduated barrel reading can omit a fixed connecting or sensor volume occupied by the same sealed gas. For a common settled temperature, Boyle's law then requiresThis second relation makes a graph of against a straight line; its intercept divided by its slope estimates under these assumptions. Unequal temperatures between the barrel and the connecting space require a different correction, analogous to the gas thermometer dead-space correction.
For an original hypothetical example, let , , , and . The total volume falls from to , so , rather than . The omitted volume makes the total compression ratio smaller than the barrel-reading ratio. These stipulated values are independent of the manufacturer's apparatus correction and are not measurements.