Mechanical ventilation

ID: mechanical-ventilation

Mechanical ventilation assists or replaces the movement of gas into and out of the lungs using a machine. A ventilator can deliver that assistance through a mask or a breathing tube.[ref] This supports pulmonary ventilation; it does not replace every function of the lungs, circulation or gas exchange.
In positive-pressure ventilation, pressure applied at the airway opening helps drive inhalation. The resulting tidal volume depends on both that pressure history and respiratory mechanics. For a passive single-compartment model, a useful equation is
Here is volume above the selected end-expiratory reference, is respiratory-system compliance, is airway resistance, and represents the baseline positive end-expiratory pressure. The model neglects active respiratory muscle pressure and changes in these coefficients.
For constructed L/cm HO, cm HO·s/L, L, L/s and cm HO, the predicted airway pressure is cm HO. At zero flow with the same volume, the resistive term vanishes and the model gives 15 cm HO. Thus an airway-pressure peak contains different information from a no-flow pressure measurement. These numbers illustrate the equation, not patient settings.
The importance of testing ventilation strategies was demonstrated by a 2000 randomized trial in acute respiratory distress syndrome and acute lung injury. It compared lower and traditional tidal volume strategies indexed to predicted body weight, with different plateau-pressure limits. In 861 participants, reported mortality was 31.0% versus 39.8%.[ref] The experiment compared complete specified protocols in a defined population; it does not establish one universal setting from tidal volume alone. Physical models explain how pressure and flow interact, while controlled clinical evidence tests consequences that those models cannot supply by themselves.