For a long vacuum-core or air-core solenoid with fixed geometry and linear magnetic response, neglecting end effects gives self-inductanceHere is the total number of turns, is the solenoid turn density, and is the interior cross-sectional area. The reason for the square of is physical: more turns produce more magnetic field, and more turns link the resulting magnetic flux. Approximately equal magnetic flux through each turn gives magnetic flux linkage ; division by the electric current yields . [ref]
https://s3.amazonaws.com/edx-textbooks/mit_802_textbook/Chapter11.pdf. MIT 8.02 course notes, Example 11.2: self-inductance of a solenoid
.For the same , , and , the area is . The long-coil estimate isAt , each turn links approximately and the total magnetic flux linkage is approximately . Their ratio to is the stated self-inductance. A real finite coil need not give precisely these values: the axial centre correction above is not by itself a correction formula for inductance, which depends on magnetic flux across all the turns.
At fixed and , doubling quadruples . At fixed solenoid turn density and area , doubling doubles both and . These are different changes to the geometry, so there is no contradiction between at fixed and at fixed . A magnetic core requires its own magnetic permeability model; nonlinear magnetization can make a constant- description inadequate.
New to topics? Read the docs here!