The arteriovenous oxygen content difference is arterial oxygen content minus the venous oxygen content leaving the same tissue bed:
It measures oxygen removed per unit volume of blood. For the whole body, the venous term is mixed venous oxygen content; for coronary oxygen uptake, the arterial and venous sampling sites must represent the coronary circulation. Oxygen content includes both hemoglobin-bound and dissolved oxygen, so this quantity is not simply the difference between two oxygen saturation readings.[ref]
If and mL/dL, then mL/dL. With blood flow dL/min, the Fick principle gives oxygen consumption mL/min. The same content difference at half the blood flow gives half the oxygen transfer. Conversely, at fixed oxygen transfer, a fall in blood flow requires a larger content difference in the steady-state balance.
Subtraction also has a useful measurement uncertainty structure. If are the standard uncertainties of the two content measurements, then
The covariance term accounts for shared errors.[ref] A common additive offset cancels in the difference, whereas a common multiplicative gain error scales the difference. Matched sampling and knowledge of shared measurement calibration errors can therefore matter as much as the repeatability of either measurement separately.