The atrial delayed-ejection flow component comprises blood leaving the left atrium during ventricular diastole after entering during the preceding diastole or earlier. The Bäck study calls this delayed outflow. In contrast, the atrial reservoir flow component enters during the intervening ventricular systole.[ref]
This is a transport-history definition, not a statement that ventricular electrical activation was delayed. A constructed timeline illustrates it. Number successive one-second cardiac cycles so the current ventricular systole occupies s and its following diastole occupies s. Suppose a parcel entered in the previous diastole at s and crosses the mitral valve at s. Its 0.8 s passage spans a ventricular systole. A second parcel entering at s and leaving at s instead belongs to the atrial conduit flow component.
For represented parcels with exit times , entry times and volume weights , a volume-weighted transit time within a selected exiting category is
Two hypothetical parcels representing 1 and 3 mL and taking 0.8 and 1.2 s give s, rather than the unweighted mean of 1 s. If an entry occurred before the available record, the exact transit time is unknown: an observed exit can establish a category without recovering an exact entry date.
The atrial delayed-ejection flow component thus complements the atrial retained-inflow component: one identifies an observed exit of older atrial blood, while the other identifies entered blood still present at the specified endpoint.