For constant-mass density incompressible flow, the displacement thickness measures the lost volume flux per unit span divided by the outer velocity:
An outer inviscid flow encountering the same volume flux deficit behaves, at leading order, as though the wall were displaced outward by . In a Blasius boundary layer, numerical integration gives . This equivalent displacement is smaller than the boundary layer thickness and is not the position of a physical surface.[ref]