The boundary probability of an empty detector-width confidence set is the chance that a valid uncertainty procedure yields no admissible nonnegative response width when the true variance difference is at its boundary. Under the explicit model , , take the central interval . The empty physical confidence set for a detector variance difference occurs when its upper endpoint is negative:
This probability decreases with , so the largest value over the physical parameter range occurs at . If is the usual two-sided normal critical value, the boundary probability is .
At that boundary the other way to miss zero is a strictly positive lower endpoint. The two tail events are disjoint and each has probability ; the remaining probability produces a confidence set containing zero. The joint probability of empty and strictly positive detector-width intervals therefore accounts for the full two-sided noncoverage, not just the empty cases.
For an original repeated-measurement calculation, use and 400 independent measurements of a stipulated zero response-variance difference. The expected number of empty physical sets is approximately ten, with standard deviation , where . The count follows a binomial distribution only under the stated independent, common-probability model. Roughly ten additional intervals are expected to lie wholly above zero. Their existence is compatible with approximately 95 percent coverage at the boundary.
For an interior example , the empty-set probability falls to . Empty results are thus most common near the resolution boundary, where subtracting similar measured variances is already delicate.
NIST explains that interpreting expanded uncertainty as a confidence interval requires distributional assumptions.[ref] These probabilities assume an actual normal model with known ; they are not inferred merely from an error bar labelled standard uncertainty. Correlation, systematic offsets or a misspecified detector response can change the repeated-measurement behavior. Retaining empty results in the record allows that behavior to be assessed rather than hiding it by replacing them with zero-width estimates.
The negative covariance of empty and positive detector-interval counts arises because a fixed number of measurement intervals is divided into mutually exclusive categories. Let indicate that interval is respectively physically empty or strictly positive. The same interval cannot satisfy both, so and
For independent repetitions with common probabilities, the counts and therefore have
The joint probability of empty and strictly positive detector-width intervals gives the underlying multinomial model. The sign describes category-count dependence, not physical antagonism between two detectors.
For an original boundary example, take and . Each count has variance , while their covariance is . The total tail-category count has variance . Treating the two counts as independent would give instead. The covariance is needed even though the individual measurement repetitions are independent.
Conditioning on the total is important. If the number of repetitions is random and independent of the category assignments, the law of total covariance gives
An independent total with a Poisson distribution has equal mean and variance, making this covariance zero; a more variable total can make it positive. This is a different sampling protocol, not a contradiction of the fixed-total formula.
Shared calibration drift is another change of model. Repetitions may then have dependent category indicators, and cross-repetition covariance terms must be added. Overdispersion of detector-interval counts under shared drift can make a simple multinomial analysis inadequate.
NIST's measurement guidance retains common influences in uncertainty propagation and requires assumptions for confidence-level interpretation.[ref] State whether the repetition total is fixed, how the categories are defined and which calibration influences are shared before interpreting their empirical count covariance.