The all-even reflection is allowed. Here and . Its normal is from and can lie in the horizontal scattering plane in an edge-aligned mounting. Nevertheless it is not parallel to the large face, so the ordinary coupled symmetric scan misses it.
Independent sample rotation can bring the normal onto the Bragg bisector, but there is an important specimen constraint: is less than the surface inclination. One ray then traverses the slab rather than emerging from the incident face. Thus a thin transmission specimen or access through another face can permit detection after suitable remounting, whereas a thick absorbing slab in front-face reflection is unfavourable. A -cut crystal allows a straightforward symmetric measurement, and a powder specimen supplies the needed orientations. Unlike , no extinction prohibits it; whether the original portable mounting can reach it depends on independent rotation, holder clearance and the transmitting path.