Use a gravity-current box model: approximate the current by uniform depth and length , with constant reduced gravity, no deposition and no fluid entrainment. The triangular cross-sectional area is , so the fixed released volume is
The Benjamin deep-ambient front condition closes the integral model:
For a finite initial length , direct integration gives
The ideal point-release limit takes and has , . Its divergent initial depth is outside the shallow water approximation, so a real finite reservoir regularizes the early stage. This is the finite-volume triangular-channel current integral law; it does not assert a spatially uniform exact solution of the local equations.