parity reverses spatial coordinates and polar vectors such as momentum, while leaving axial vectors such as angular momentum unchanged. The correlation is therefore parity odd. For polarized beta-emitting nuclei one can measurewhere is measured from nuclear polarization, its magnitude and a decay-dependent coefficient. A nonzero spin–momentum asymmetry is incompatible with parity invariance.
The cobalt-60 experiment polarized nuclei at low temperature and compared beta emission along and opposite the polarization axis. Preferential emission on one side established weak-interaction parity violation. Reversing polarization tests whether the asymmetry follows nuclear orientation; warming the sample removes polarization, while gamma anisotropy monitors its loss. Detector acceptance, backgrounds and magnetic deflection of charged particles must be separated from a true emission asymmetry.[ref]
Experimental Test of Parity Conservation in Beta Decay by Chien-Shiung Wu and others. 1957, polarized cobalt-60 experiment and temperature/polarization checks
In the modern weak charged current, the V-A interaction couples to left-chiral fermion fields. In the massless limit this selects left-helicity neutrinos and right-helicity antineutrinos. Massive charged leptons need not be pure-helicity states, consistent with the factor . Strong and electromagnetic interactions conserve parity to the usual experimental approximation; parity violation alone should not be confused with CP violation or a failure of CPT.