Protocol-dependent accessibility of lung gas means that the volume reached by a tracer gas depends on how long and how the tracer gas is allowed to mix. Gas that communicates slowly can be partly represented during one observation window and more fully represented during another. This differs from assuming that one fixed volume is permanently isolated.
An original compartmental model makes the dependence quantitative. A reservoir of volume initially contains helium fraction and rapidly mixes with a fast lung region . Their combined volume is , with initial fraction . A slow region of volume initially contains no tracer gas and exchanges equal gas volumes in each direction at rate . Assuming constant volumes and well-mixed compartments,
Total tracer gas is conserved, while the concentration difference decays with
Applying an equilibrium dilution formula before equilibration gives an apparent lung volume . It starts at and tends toward in this ideal model.
For stipulated L, L, L, and s, the recorded concentration is . After 10 s, the apparent volume is about 4.13 L; after full equilibration it is 5 L. The change occurs without adding lung gas: the tracer gas is reaching more of the existing volume. These are constructed mixing calculations, not a clinical waiting-time recommendation.
The primary respiratory text describes a closed-circuit helium apparatus with continuous concentration measurement using a thermal-conductivity meter, together with gas-volume corrections. It also states that poor communication and short dilution time can limit the represented gas volume.[ref] Leaks, changing gas conditions and unequal starting volumes can produce additional differences. A protocol-defined apparent volume therefore needs its mixing and measurement conditions attached to the result.