B. Shaanan 2026-11-05
B. Shaanan determined a human oxyhemoglobin structure by single-crystal X-ray crystallography in a 1983 paper bearing that exact single-author byline. The experiment used an Arndt–Wonacott camera at and reported a resolution of .[ref]
Structure of human oxyhaemoglobin at 2.1 A resolution by B. Shaanan. Byline; Abstract, diffraction apparatus and resolution
It supplied an experimental arrangement against which molecular explanations of hemoglobin oxygen binding could be tested.The paper distinguished the local environments in the alpha-globin and beta-globin subunits and specified iron positions relative to defined porphyrin planes. Shaanan also coauthored the later deoxyhemoglobin study with G. Fermi, Max Perutz and R. Fourme.[ref]
The crystal structure of human deoxyhaemoglobin at 1.74 A resolution by G. Fermi and others. Primary byline
Comparing the two ligation states requires consistent geometric definitions; distances from different reference planes are different observables.An original plane-fitting example makes that distinction concrete. A point at coordinate angstrom is 0.30 angstrom from the plane , but only 0.10 angstrom from the parallel plane angstrom. The atom has not moved. Changing the atoms used to define a fitted plane can change a reported displacement.
For a unit normal and point on a reference plane, signed distance from position isReversing the normal reverses the sign; translating both the model and its plane by the same vector leaves unchanged. These are geometric checks for interpreting a structural comparison, not additional measurements from the paper.
The value of the structural work is therefore more specific than an image of a protein: it turns questions about oxygen-binding geometry into quantities with stated reference conventions and experimental support. The published initials are retained rather than assuming a full identity from a similarly named crystallographer.
R. Fourme 2026-11-05
R. Fourme coauthored the 1984 high-resolution structure of human deoxyhemoglobin with G. Fermi, Max Perutz and B. Shaanan. The primary record describes X-ray diffraction collected on film at room temperature using synchrotron radiation, followed by refinement at resolution.[ref]
The crystal structure of human deoxyhaemoglobin at 1.74 A resolution by G. Fermi and others. Primary byline and Abstract, experimental apparatus
This establishes a contribution to experimental structural biology; the byline alone does not assign each instrument or calculation to one coauthor.The physical chain is illuminating: a crystal scatters the incident radiation, a detector records diffraction intensity, and a model connects the measurements with an electron density distribution. Improving incident flux can help collect weak reflections, but flux and spatial resolution remain different quantities.
For an original counting example, suppose an ideal detector records 400 independent photons in one reflection and background is negligible. A Poisson distribution then gives standard uncertainty counts, or 5% relative uncertainty. Four times as many recorded photons gives 1,600 counts and relative uncertainty. The square-root improvement describes the chosen counting model; it is not a measured uncertainty for the historical film detector.
Increasing exposure also need not preserve the specimen unchanged. A comparison should keep track of radiation-induced changes, detector response and background rather than assuming that every additional count is interchangeable. Those experimental controls complement the molecular constraints used in X-ray crystallography. Fourme's verified coauthorship connects the biological question to the apparatus needed to obtain its structural evidence.