The worst-switching-phase settling bound for a first-order circuit maximizes the initial transient over the source's unknown switching wave phase. For the stable RC circuit, let its sinusoidal particular solution be , where , and let be the initial capacitor electric potential difference. The error identity in exponential settling bound for RC sinusoidal turn-on givesSince ranges from minus one to one,For a validated initial bound , the sharp uniform bound is therefore . It is attained by choosing the extreme initial value and the opposite steady-state wave phase. A normalized error tolerance is guaranteed thereafter ifThere is no division by the instantaneous sinusoid, so its zero crossings cause no singular relative-error specification.
For an original example, choose , , , and . The worst-case settling time is . Assuming an uncharged capacitor instead would give . That shorter guarantee requires the additional initial-state information.
A phase-locked test can measure a smaller mismatch, even zero for a specially matched initial condition, without contradicting the worst-case result. A valid comparison records both the switching wave phase and the capacitor's initial state. The MIT laboratory's square-wave natural-decay observation and sinusoidal amplitude/wave phase measurement provide the two underlying bench measurements.[ref]
Laboratory 11: Sinusoidal Steady State Response of RC and RL Circuits by MIT OpenCourseWare. Printed pp. 1–2
The result assumes the same linear first-order model throughout switching; additional modes or a time-varying component require another transient bound. Articles by others on the same topic