Hardware for Quantum Computing by Chuck Easttom by
Ciro Santilli 35 Updated 2025-04-05 +Created 2024-11-15
This book is mostly a failure unfortunately, as it glosses far too quickly over the physical implementations.
Published as A New Method of Measuring Nuclear Magnetic Moment.
Bibliography:
As of 2024 this was the one making the most likely promises of being the first decentralized exchange to support Monero.
Quantum computing hardware bibliography by
Ciro Santilli 35 Updated 2025-04-05 +Created 2024-11-15
The Molecular Beam Resonance Method for Measuring Nuclear Magnetic Moments by
Ciro Santilli 35 Updated 2025-04-05 +Created 2024-11-15
Paywalled as of 2024.
Physical Review Volume 55, Issue 6.
This is almost certainly detailed paper that the one pager A New Method of Measuring Nuclear Magnetic Moment promises at the end, they mention:and reference A New Method of Measuring Nuclear Magnetic Moment.
In two letters to this journal, we reported briefly on a new precision method of measuring nuclear moment, and on some results. In this paper we shall give a more detailed account of the method, apparatus and results.
A New Method of Measuring Nuclear Magnetic Moment by
Ciro Santilli 35 Updated 2025-04-05 +Created 2024-11-15
Physical Review Volume 53, page 318.
Not paywalled as of 2024! A miracle! It is barely one page long.
This is the paper that contains the first successful report of experimental nuclear magnetic moment observation.
They promise more at the end:and this promise was fulfilled on the later The Molecular Beam Resonance Method for Measuring Nuclear Magnetic Moments.
We have tried this experiment with LiC1 and observed the resonance peaks of Li and Cl. The effects are very striking and the resonances sharp (Fig. 1). A full account of this experiment, together with the values of the nuclear moments, will be published when the homogeneous field is recalibrated.
This figure sums it all up: they were measuring the intensity of one side of a molecular beam after a Stern-Gerlach experiment.
Then, they vary the constant magnetic field before the splitting, and at the same time apply a fixed radio frequency to the beam.
When the constant magnetic field makes the energy gap match the radio frequency input, nuclear spin of many atoms goes to the anti-aligned direction, the beam gets diverted, so the previously detected beam gets weaker.
Journal by the American Physical Society by
Ciro Santilli 35 Updated 2025-04-05 +Created 2024-11-15
The goal of our broken educational system is not to teach.
It is simply a test of who can learn the most in the least amount of time.
What is being learnt is of little importance. it doesn't matter if it is useful or beautiful things.
The useless exams are set exactly at a difficulty level that produces a normal distribution of grades:The difficulty is just set for your particular group of students.
- too hard and everyone gets 0, so you can't split people well
- too easy and everyone gets 100, so you can't split them well either
Unlisted articles are being shown, click here to show only listed articles.