Topics (384k) Articles (398k) Users (410) Discussions (242) Comments (383) Files (13k) New article
This well-founded relation is well-founded without the axiom of choice or Axiom of foundation. If a nonempty set lacked a minimal member, put . For each , some has , and gives . Hence . The Cantor diagonal argument applied to contradicts this inclusion.
This relation has well-foundedness without Axiom of foundation or axiom of choice. If a nonempty set had no minimal member, put . For each , choose existentially an with . Since , every subset of belongs to . Thus . But is then an element of , contradicting .
A Weil divisor is Q-Cartier if some positive integer multiple is a Cartier divisor. Its Cartier index is the smallest such integer. It is ample in the Q-Cartier sense when such a multiple is an ample Cartier divisor. This need not make the original divisor itself Cartier.
Apparent weight measures support rather than the gravitational force itself. In an ideal scale model, it is the magnitude of the normal force exerted on the body. A scale calibrated to display mass divides that support force by its calibration value of .
Take upward as positive in a constant downward gravitational acceleration of magnitude . If a body stays in contact with a horizontal scale and accelerates upward at , Newton's second law gives , hence . At rest, . In common free fall, , so despite the nonzero gravitational weight . If the formula would require , ordinary supporting contact cannot realize it: the body loses contact instead.
Exterior multiplication by a fixed differential form is the linear operator taking the wedge product of differential forms on the left. For a one-form , it raises degree by one. Anticommutativity gives for one-forms. On the exterior algebra of an inner product space, pairing this operation with contraction produces Clifford multiplication .
The Szlenk index measures how many transfinite Szlenk derivations are needed to empty the dual unit ball at each positive norm-diameter scale. At a successor ordinal take another derivation; at a limit ordinal intersect the previous sets. Taking the supremum of the emptying ordinals over the positive scales gives an ordinal invariant of the Banach space.
The weak neutral current couples the Z boson to a fermion without changing its electric charge. Its vector and axial-vector coefficients depend on weak isospin, electric charge, and the weak mixing angle.
The neutral current transfers no electric charge at a fermion vertex; “neutral” does not mean that every participating particle is uncharged. For example, transfers energy and momentum to an electron through Z boson exchange. By contrast, a charged current can convert a muon neutrino into a muon, as in . Both processes conserve total electric charge. A photon also carries no electric charge, but an active neutrino has no electromagnetic charge coupling: its neutral current is a distinct weak interaction.
The experimentally useful contrast on a nucleon target iswhere is a nucleon and is an allowed final state of hadrons. The charged current makes a charged lepton available for identification; the outgoing neutrino in a neutral current leaves no bubble-chamber track. A sample of hadronic events without an identified muon therefore poses an experimental question: how many could instead be neutron interactions, or charged current events whose muon was missed? The answer requires a detector-response and background analysis, not merely an inspection for an absent line.
The weak charged current couples a W boson to two members of a left-handed electroweak doublet. In the quark mass basis its flavor coefficients are entries of the Cabibbo-Kobayashi-Maskawa matrix.
The trace of the angular derivative of the reduced deflection defines convergence in the standard thin gravitational lens equation convention. It equals projected surface mass density divided by the critical surface density, . If deflection is instead defined as source minus image angle, the divergence relation has a minus sign.
The trace-free part of the angular lensing-potential Hessian stretches an image anisotropically. The source-image Jacobian matrix has eigenvalues . Thus a circular source becomes an ellipse in the local linear approximation; the orientation follows the shear axes.
Cosmic shear is the statistically correlated lensing shear of distant galaxies produced by the intervening large-scale matter distribution. Correlations across angle and source redshift constrain clustering, the growth of structure and distance geometry, thereby testing dark matter and dark energy. Intrinsic galaxy alignments and measurement errors must be separated from the lensing signal.
The first level of this group path is zero but its second level grows linearly. Its Carnot-Carathéodory distance increments are a constant times . It therefore has finite -variation precisely when , and is a step-two weak geometric rough path at , even though its first-level trace is constant. For higher truncations the same Lie exponential defines a compatible lift.
A torsion-balance comparison of the gravitational acceleration of bodies of different composition, testing equality of inertial and passive gravitational mass up to a universal proportionality factor. A universal acceleration law independent of test-body mass and composition agrees with this weak equivalence principle test. It does not by itself establish the strong equivalence principle for self-gravitating bodies.
An analytical concentration records the total conserved inventory of a specified component per volume of chemical solution, summed over its relevant chemical species. Here ; it is not generally the chemical equilibrium concentration of the undissociated weak acid.
A burette delivers an adjustable measured volume of a chemical solution; the change in its reading gives the delivered volume in an acid-base titration.
Its downward-increasing scale measures a change in reading, not the initial liquid inventory. For initial reading and final reading without refilling, the nominal delivered volume is . An illustrative to reading therefore represents . There is no requirement to start at zero. An air bubble disappearing from the tip uses part of the apparent delivery to fill the tip, and a hanging drop has not yet entered the sample; both break the intended volume account.
For transparent aqueous samples, read the bottom of the liquid meniscus at eye level; viewing from above or below shifts its apparent alignment. The mark is a comparison between a curved liquid surface and a scale, not a direct measure of amount of substance. Eye-level reading and the distinction between contained and delivered volumes are part of solution preparation and volumetric calibration.[ref]
Calibration of Volumetric Glassware (Buffalo State laboratory handout). Laboratory Experiment 1. Calibration of Volumetric Glassware, p. 1, eye-level bottom-of-meniscus reading
Both readings contribute measurement uncertainty. If each has independent standard deviation , their difference has standard deviation ; a common additive reading offset cancels, while a scale-factor error remains. For the inventory , uncertainty in titrant concentration remains even with perfect readings. This is why repeat delivery, independent volume calibration, and titrant standardization answer different questions.
For an acid-base titration, a volumetric pipette selects an aliquot whose amount of substance is from a homogeneous sample. The delivered volume depends on the instrument's calibration and drainage convention; the residual liquid of a gravity-draining volumetric pipette is allowed for in that calibration. Its mark is read using the liquid meniscus. A volume calibration alone does not establish that the sampled chemical solution has the intended concentration.[ref]
Calibration of Volumetric Glassware (Buffalo State laboratory handout). Laboratory Experiment 1. Calibration of Volumetric Glassware, pp. 1–2, Calibrating 25 mL pipette: eye-level meniscus, gravity drainage, retained liquid
A volumetric flask prepares a chemical solution at a specified total volume, using a calibration mark.
Its mark specifies contained volume under its calibration conditions. In contrast, a volumetric pipette specifies a delivered portion. The narrow neck makes a small change of volume visible as a larger change of liquid height. The final chemical solution volume includes the solute; “dilute to ” does not mean “add of water”.[ref]
Calibration of Volumetric Glassware (Buffalo State laboratory handout). Laboratory Experiment 1. Calibration of Volumetric Glassware, p. 1, distinction between contained and delivered volumes and flask calibration principle
For an original dilution example, a fully transferred aliquot of acid contains . Making the final total gives analytical concentration . A subsequent aliquot contains and needs of base for one-to-one neutralization. The entire diluted flask still needs of that base: dilution preserves the selected inventory but sampling selects a fraction of it.
Overfilling lowers the intended molar concentration. Removing some well-mixed chemical solution to restore the mark also removes solute, so it does not recover the intended inventory. Full transfer, known final volume, and mixing are separate requirements.
An acid-base titration adds measured quantities of a standardized chemical acid or chemical base to determine an initially unknown acid or base inventory through neutralization. Monitoring pH also constrains chemical equilibrium parameters such as the acid dissociation constant.
The added reagent is the titrant; a pipette selects an aliquot of the sample and a burette measures the added volume. Known stoichiometry converts this volume into amount of substance. This separates two questions that a single pH reading cannot answer: how much chemical acid is present, and how readily it donates a proton. A large inventory of weak acid can consume more titrant than a small inventory of strong acid despite having a higher initial pH.
A reference electrode supplies the comparison electric potential for the glass electrode measurement. A combination probe incorporates both electrodes; changes at its junction can contribute measurement error.
A glass electrode is an electrode whose glass membrane responds to hydrogen ion thermodynamic activity. A meter measures its electric potential difference against a reference electrode; calibration with standard buffer solutions converts this response to operational pH.
Pinned article: Introduction to the OurBigBook Project
Welcome to the OurBigBook Project! Our goal is to create the perfect publishing platform for STEM subjects, and get university-level students to write the best free STEM tutorials ever.
Everyone is welcome to create an account and play with the site: ourbigbook.com/go/register. We belive that students themselves can write amazing tutorials, but teachers are welcome too. You can write about anything you want, it doesn't have to be STEM or even educational. Silly test content is very welcome and you won't be penalized in any way. Just keep it legal!
Intro to OurBigBook
. Source. We have two killer features:
- topics: topics group articles by different users with the same title, e.g. here is the topic for the "Fundamental Theorem of Calculus" ourbigbook.com/go/topic/fundamental-theorem-of-calculusArticles of different users are sorted by upvote within each article page. This feature is a bit like:
- a Wikipedia where each user can have their own version of each article
- a Q&A website like Stack Overflow, where multiple people can give their views on a given topic, and the best ones are sorted by upvote. Except you don't need to wait for someone to ask first, and any topic goes, no matter how narrow or broad
This feature makes it possible for readers to find better explanations of any topic created by other writers. And it allows writers to create an explanation in a place that readers might actually find it.Figure 1. Screenshot of the "Derivative" topic page. View it live at: ourbigbook.com/go/topic/derivativeVideo 2. OurBigBook Web topics demo. Source. - local editing: you can store all your personal knowledge base content locally in a plaintext markup format that can be edited locally and published either:This way you can be sure that even if OurBigBook.com were to go down one day (which we have no plans to do as it is quite cheap to host!), your content will still be perfectly readable as a static site.
- to OurBigBook.com to get awesome multi-user features like topics and likes
- as HTML files to a static website, which you can host yourself for free on many external providers like GitHub Pages, and remain in full control
Figure 2. You can publish local OurBigBook lightweight markup files to either OurBigBook.com or as a static website.Figure 3. Visual Studio Code extension installation.Figure 5. . You can also edit articles on the Web editor without installing anything locally. Video 3. Edit locally and publish demo. Source. This shows editing OurBigBook Markup and publishing it using the Visual Studio Code extension. - Infinitely deep tables of contents:
All our software is open source and hosted at: github.com/ourbigbook/ourbigbook
Further documentation can be found at: docs.ourbigbook.com
Feel free to reach our to us for any help or suggestions: docs.ourbigbook.com/#contact






