Common-origin pressure-tap position error
ID: common-origin-pressure-tap-position-error
A common-origin pressure-tap position error shifts several inferred tap positions together relative to a fixed physical reference. It is a shared contribution to correlated position errors of pressure taps, not an independent placement error for every hole. Whether it affects a pressure-derived load depends on which references are held fixed.
For dimensionless chord coordinate , suppose the uncertain displacement is the same scalar for every tap. A first-order Taylor expansion of the pressure coefficient gives . For a reconstruction with fixed quadrature weights,The position covariance matrix is , a rank-one matrix. Squaring each tap's contribution before adding would discard the shared covariances. The covariance terms belong in the general propagation of uncertainty.[ref]
An original locally linear example takes eight equal weights , equal local slopes and . The reconstructed coefficient has standard uncertainty . Incorrect independence would give . If a two-dimensional load per span is with stipulated dynamic pressure Pa and airfoil chord m, these become and N/m. The chosen slopes describe a sensitivity model, not measured airfoil data.
Opposite-signed sensitivities can cancel the shared contribution. Conversely, repeating coordinate readings without independently checking the misplaced datum cannot average away its fixed error. A proposed test measures an independent reference mark and deliberately translates the assumed origin in the reconstruction, comparing the observed load sensitivity with the derivative above. If moving coordinates also changes the integration weights, those additional derivatives must be included.
Pressure-tap datum cancellation is a different situation. When the tap, leading edge and trailing edge are all expressed through the same affine map , with ,The common origin and scale cancel exactly. Merely translating a shared coordinate system causes no physical tap misregistration. Affine pressure-tap coordinate calibration must therefore state whether the datum is shared or independently fixed before assigning a common-origin uncertainty.