Threshold-reset margin for a periodic RC pulse train
ID: threshold-reset-margin-for-a-periodic-rc-pulse-train
The threshold-reset margin for a periodic RC pulse train is the separation between the reset threshold of an electronic comparator and the largest baseline that the periodic RC low-pass filter may leave between pulses. A positive margin excludes missing comparator reset in an RC pulse train in the ideal threshold model; its size measures tolerance to additional electric potential difference errors.
Let be the input high level, the high duration, the quiet duration and the time constant. From the periodic solution in missing comparator reset in an RC pulse train, writeThis defines a margin in volts, rather than in units of standard deviation. If a nominal baseline has a known absolute error bound and the reset threshold has bound , a sufficient worst-case condition isThese are simultaneous bounds on the actual baseline and threshold. Adding their standard uncertainties would not by itself provide a deterministic guarantee; a probabilistic statement requires a specified joint probability distribution.[ref]
Guidelines for Evaluating and Expressing the Uncertainty of NIST Measurement Results by Barry N. Taylor and Chris E. Kuyatt. §§6.2–6.3, distributional conditions for interpreting uncertainty intervals
For an original example, let , and . Then , and the peak is . A threshold of gives . Bounds and leave . Raising the baseline bound to would remove this guarantee even though the nominal waveform still crosses the threshold.
A positive minimum separation does not specify the reset dwell time below threshold in an RC pulse train. A real electronic comparator needs enough time to switch, and the peak must separately exceed the acceptance threshold. For a Schmitt trigger, use the lower switching threshold in , while checking the upper one against the peak.
A focused bench test records the pulse generator output, capacitor output and electronic comparator output on an oscilloscope, then varies near the predicted boundary. Compare the measured minimum with the reset threshold and record the low interval as well as the minimum. The underlying exponential decay can be checked by the natural-response experiment in the MIT laboratory; the margin calculation above is an original application of that model.[ref]
Laboratory 11: Sinusoidal Steady State Response of RC and RL Circuits by MIT OpenCourseWare. Printed p. 1, capacitor response after switching and time-constant measurement