The time constant τ>0 in exponential decay is the time over which the decaying quantity is multiplied by e−1. A response approaching equilibrium as q(t)=q∞+(q(0)−q∞)e−t/τ has the same time constant. For a resistor-inductor circuit it is L/R.
Ancestors (5)
Incoming links (109)
- Actuator lag
- Adiabatic process
- Analog switch on-resistance
- Baseline-trajectory dependence of local respiratory time constants
- Calorimeter heat-loss correction
- Common offset in RC timing
- Correlated threshold and amplitude errors in RC timing
- Delay stability of proportional integrator control
- Differential thermal model of a sun valve
- Discrete-jump model of Barkhausen noise
- Early-time resistance dominance of a filling response
- Electrical calorimetry of a resistor
- Electrical circuit
- Envelope detector
- Equal-loop RL induction step
- Filtered shot noise
- Finite-time ambiguity between stiffness and slow filling
- Finite-window lock-in response
- First-order low-pass filter
- Free viscous decay between parallel plates
- Heat bath relaxation with finite capacity
- Homeostatic temperature model
- Inductive transient
- Initial value problem
- Input capacitance
- Jeffrey Lang
- Karl K. Berggren
- Leaky integrate-and-fire model
- Low-temperature heat capacity measurement
- Metabotropic receptor
- Mismatch remaining after common RC gain cancellation
- Neuron
- Operating-point time constants with nonlinear airway resistance
- Passive membrane response in current clamp
- Passive spatial and conductance integration
- Past exam of the biological physics course of the University of Oxford / 2015 / 5 / b / Solution
- Past exam of the biological physics course of the University of Oxford / 2016 / 8 / b / Solution
- Past exam of the biological physics course of the University of Oxford / 2017 / 1 / b / Solution
- Past exam of the biological physics course of the University of Oxford / 2018 / 3 / d / Solution
- Past exam of the biological physics course of the University of Oxford / 2022 / 4 / a / Solution
- Past exam of the mathematical physiology course of the University of Oxford / 2023 / 2 / a / Solution
- Past exam of the mathematical physiology course of the University of Oxford / 2023 / 2 / b / Solution
- Past exam of the mathematics course of the University of Cambridge / 2014 / ib / Paper 4 / 7A / Solution
- Past exam of the MPhil in micro- and nanotechnology enterprise course of the University of Cambridge / 2017 / Paper 1 / Section A(iii) / 7 / Solution
- Past exam of the physics 2 paper of the University of Oxford / 2014 / 9 / iii / Solution
- Past exam of the physics 2 paper of the University of Oxford / 2014 resit / 6 / Solution
- Past exam of the physics 2 paper of the University of Oxford / 2018 / 9 / c / Solution
- Past exam of the physics 2 paper of the University of Oxford / 2018 / 9 / d / i / Solution
- Past exam of the physics 2 paper of the University of Oxford / 2019 resit / 5 / Solution
- Past exam of the physics 2 paper of the University of Oxford / 2022 / 1 / i / Solution
- Past exam of the physics A course of the University of Cambridge / 2018 / Paper 1 / Section A / A5 / Solution
- Past exam of the physics course of the year 1 of the natural sciences course of the University of Cambridge / 2016 / Paper 1 / Section C / C10 / a / Solution
- Past exam of the physics course of the year 1 of the natural sciences course of the University of Cambridge / 2018 / Section E / 15 / c / Solution
- Past exam of the short options paper shared by Prelims and Parts A and B of the physics course of the University of Oxford / 2017 / S25 / 3 / 1 / Solution
- Patch-clamp series resistance
- Peak flow meter
- Periodic RC pulse-train baseline
- Phenomenological paired-pulse recovery
- Philip Drinker
- Quiet interval required for an RC baseline timing budget
- Ratiometric cancellation of RC timing gain errors
- Ratiometric cancellation with matched signal and reference filters
- RC charging circuit
- RC circuit
- RC low-pass filter
- RC low-pass laboratory
- RC low-pass output loading
- RC low-pass step response
- RC pulse-width discrimination
- Reference signal
- Reset dwell time below threshold in an RC pulse train
- Reset error budget with a persistent pedestal
- Residual baseline in RC pulse-width discrimination
- Resistor-capacitor equilibrium noise
- Reversible receptor phosphorylation model
- Rise time
- RL circuit
- RL low-pass filter
- Secant versus differential airway resistance
- Sequential excited-state population kinetics
- Shunting inhibition
- Signaling adaptation
- Signaling feedback
- Sinusoidal steady state
- Source-fed parallel resistor-inductor switching
- Spark-excited damped oscillation
- Spirometry
- Static versus dynamic lung compliance
- Synaptic potential
- Synthetic insulin-glucagon response model
- Tail-volume loss and ratio inflation in truncated expiration
- Temperature sensor response time
- Terminal velocity under linear drag
- Testing a differential thermal actuator
- Thermal equilibration of two finite bodies
- Thermal loading by a contact temperature sensor
- Thermometer
- Thermopile radiative measurement
- Thermopile thermal response
- Threshold-crossing time of a finite rectangular pulse through an RC load
- Threshold-reset margin for a periodic RC pulse train
- Time scale
- Tracking error
- Two-bath step test of a temperature sensor
- Two-state ion-channel gating
- Unequal filling times in apparent lung compliance
- Vacuum
- Zero-input response
- Zero-state response
Discussion (0) New discussion
There are no discussions about this article yet.
Articles by others on the same topic (1)
The time constant is a measure that characterizes the time response of a system, typically in the context of first-order linear systems, such as electrical circuits (like RC circuits) and mechanical systems (like damped harmonic oscillators). It provides a way to quantify how quickly a system responds to changes in input.