Diphoton opening-angle distribution Created 2026-10-25 Updated 2026-10-31
An isotropic two-photon decay of a massive parent with laboratory Lorentz factor has the displayed normalized opening-angle probability density, with and . To derive it in units , the laboratory photon energies are , where is uniform on . The diphoton invariant mass gives . Apply the change of variables for probability densities to both signs of . Its minimum-angle peak is an inverse-square-root singularity. At , the probability distribution is concentrated at .
The diphoton invariant mass follows by adding the two photon four-momenta: . ThusFor correlated diphoton mass resolution, at fixed angle, . If the two quoted fractional errors are independent one-standard-deviation uncertainties,An unknown common energy-scale error would be correlated: with correlation coefficient , the fractional variance is . Fully correlated scale errors give 10%, rather than 7.1%. A mass consistent with a candidate is not by itself evidence establishing its identity.
For two photons, four-momentum conservation and their vanishing rest masses give the diphoton invariant massTaking a logarithmic differential,For small mutually independent measurement errors, propagation of uncertainty consequently givesPrinted-formula correction. The source's left-hand side, if it means as its description suggests, is missing the factor on the right. Its right-hand side instead equals to first order. A concrete counterexample is a fixed opening angle and an exactly known : because , a small fractional error in produces a fractional error in , not . Likewise, interpreting literally as a small change in would make the unsquared left-hand side incompatible with the squared terms. Correlated errors require the covariance terms as well.
The space angle is determined by the two polar angles and azimuthal separation:At and , and . The angular coefficient is therefore one. Equal contribution of opening-angle uncertainty and the combined two independent photon energy errors requiresFor independent equally precise single-photon polar directions, at this geometry, soAn azimuthal error contributes only at second order about . The corresponding invariant-mass resolution from the two energy errors alone is ; with an equally large angular contribution it is . The common missing factor of four cancels when equating the two contributions, so the angular estimates remain valid despite the printed error.
Past exam of the symmetry and relativity course of the University of Oxford 2022 2 b Solution 2026-10-25
By four-momentum conservation, . With the Minkowski metric, the neutral pion has , while each photon has and . Taking the Minkowski norm givesThe half-angle identity therefore yieldsThis is a measurement of the diphoton invariant mass using two photon energies and their opening angle, independent of the neutral pion's laboratory velocity.