Mass measures a body's resistance to a change of velocity and its coupling to gravity. In Newton's second law for a body of fixed mass, , the inertial mass relates a known net force to the resulting acceleration. Applying the same force to two carts and comparing their accelerations measures their mass ratio.
A balance instead compares gravitational forces in a common gravitational field, probing gravitational mass. The proportionality of inertial mass and gravitational mass explains why freely falling bodies have the same acceleration when other forces can be neglected. Gravitational weight changes with the local gravitational field, while a body's mass need not change. In special relativity, mass-energy equivalence relates rest energy to mass through .
Tare mass is the specified container or packaging mass excluded when reporting net mass. It is also called tare weight in weighing terminology. The intended boundary matters: a jar alone and that jar with its lid have different tare masses. A tare device adjusts a weighing scale's indication with a load present, whereas a zero-setting device establishes zero with the load receptor unloaded.[ref]
A simple demonstration separates the reading from the physical load. Choose an empty container of mass and an ideal weighing scale that initially reads zero. After the container is placed on the load receptor, operate the tare device. Its displayed value becomes zero while the container's mass remains . In a uniform gravitational field with chosen magnitude , its gravitational weight is still
The supporting force remains present after the display adjustment.
In an ideal unit-gain measurement model, the tared indication for a complete load of mass is . Adding of contents gives gross mass and indication . Removing the complete load while retaining that reference gives indication . The negative indication expresses the difference from the stored reference; the removed container still has positive mass.
A preset tare device instead uses an introduced preset tare value, which can be recalled or entered without weighing each individual empty container.[ref] For the same chosen load, using a preset of gives calculated net mass : the contents are overestimated by 20 g. A persistently low preset produces a systematic error even with otherwise exact readings.
Composite tare mass includes several excluded components, such as all the jars and an outer crate. The gross mass example shows how to account for these components once each. The symbol here denotes a mass; the terminology's use of the word weight does not change the quantity's unit from a kilogram to a unit of force.
A preset tare value is a numerical tare mass entered or recalled for use in subsequent weighings without individually determining each container's tare. The pinned OIML terminology denotes it by and calls the measured gross or net indication minus this value a calculated net value. It can be supplied through a preset tare device rather than obtained by weighing the current empty container.[ref]
For an original example, a stored container tare is , but the actual empty container has tare mass . Adding of material gives gross mass . Applying the stored value gives
although the actual net mass is . Their difference is
An underestimated preset tare therefore overestimates the contents. Repeating the same discrepancy across ten containers produces a total discrepancy; more displayed digits do not remove it.
A useful physical check independently weighs representative empty containers, including the same lids and attachments used during the loaded measurement, and compares them with the stored value. Record which load components the preset represents. If it is subtracted from an indication that has already had those components removed by a tare device, the same tare mass is deducted twice. The stored number's provenance and variability belong in the measurement model and its measurement uncertainty.
A composite tare mass is the combined tare mass of several disjoint container or support components included within the chosen weighing boundary. If component contributes ,
The boundary matters: include each unwanted load component once, and exclude everything that is not on the load receptor. OIML's tare and gross/net terminology supplies the underlying weighing distinction; the component sum here is an explicit additive mass model.[ref]
For an original assembly, three empty crucibles each have mass , their three lids each have mass , and their common tray has mass . The composite tare mass is
If the loaded assembly has gross mass , its material has net mass . Subtracting the lids again after subtracting the complete tare would incorrectly give .
One can weigh the empty assembled system directly or sum separately measured component masses. For independent component standard uncertainties of per crucible, per lid and for the tray, the sum has
Shared calibration errors require covariance terms instead of this independent-input calculation.[ref] A changed lid, retained material or substituted tray changes the assembly and can invalidate a previously stored tare.
Gross mass is the mass of the complete specified load, including its contents and the packaging counted as tare mass. For that same boundary,
The gross indication in OIML's weighing terminology is obtained with neither a tare device nor a preset tare device operating, after an initial zero indication.[ref] A full crate's gross mass consequently differs from an individual jar's gross mass, because the specified loads differ.
Consider four jars, each containing of material and having an empty-container tare mass of . An outer crate adds . For the complete load, the net mass of the contents, composite tare mass, and gross mass are respectively
These are chosen bookkeeping values, assuming the listed components exhaust the load and each component is counted once.
Figure 1.
Gross, composite tare and net mass of four jars in one outer crate
. Original chosen example: 2.00 kg of contents, 0.80 kg of empty jars and 0.80 kg of outer crate. The colored parts represent disjoint portions of the complete load. Details.
Subtracting the full composite tare mass from the complete gross mass gives of contents. If the jars' has already been removed from an intermediate total, subtracting the same full composite tare mass again gives . The missing is precisely the duplicated deduction. Use one load boundary and subtract each packaging component once.
The gross mass also remains relevant to maximum weighing capacity when a subtractive tare device reduces the available net-load range.[ref] For an illustrative instrument modeled with a gross-load limit, a container leaves for contents. At that limit the complete load still has gross mass , even though the tared display reports only its contents.
For a stationary ideal weighing scale, the normal contact force associated with a complete load is related to its gravitational weight. A displayed net mass is a processed indication of that load; it is not the full supported mass. Changes in the gravitational field, measurement calibration, or the load boundary must therefore be distinguished when interpreting a reading.
Net mass is the mass attributed to the material of interest after excluding the container or other specified tare mass. For a container-and-contents measurement, the ideal bookkeeping relation is
where is the gross mass of the complete load and is the mass excluded as tare. State which parts of the load belong to each quantity.[ref]
For an own weighing example, a container and its contents give a mass estimate of , while the corresponding empty container gives . Assuming comparable conditions and no change in the container, the contents' estimated net mass is
An instrument's tare operation can instead establish the container reading as its reference before displaying a net indication for the added contents. The recommendation distinguishes this operation from subtracting a stored preset tare value.[ref]
The physical apparatus is a weighing scale: it determines mass using gravity under its measurement model. The fact that weighing terminology sometimes says weight value does not turn the result in kilograms into a force in newtons.[ref]
Subtraction also exposes how errors enter. In a simple additive model, let the two estimated masses be and . Then
A stable common additive offset cancels when ; unequal errors do not. For example, overestimating the tare by while leaving the gross estimate unchanged underestimates net mass by the same amount.
Real measurements additionally involve resolution, drift, measurement uncertainty and the definition of the load. The exact algebraic relation between ideal quantities is not a promise that independently rounded display readings always reproduce the same final digit. Record the relevant tare and measurement conditions along with the net result, rather than treating net mass as a new kind of matter independent of how the excluded mass was defined.
A calculated net value is the difference between a measured weighing value, gross or net, and a preset tare value. The key distinction is the origin of the subtracted quantity: it is entered or recalled numerically rather than necessarily being a freshly measured tare for that individual container. OIML R76-1:2006 defines these terms separately from an ordinary net indication after operation of a tare device.[ref]
Write the arithmetic as
where is the stored preset tare value. Here the weighing values are expressed as mass estimates, for example in kilograms; they are not forces expressed in newtons. The instrument determines mass using gravity under its measurement model.[ref]
For a chosen packaging example, let a loaded container give and let the stored nominal container tare be . The calculated net value is then . If this particular empty container actually has mass , its contents have ideal net mass . The calculated indication overestimates that value by . The subtraction has been performed correctly; the discrepancy arises because a nominal tare was substituted for an individual one.
More generally, let the true contents' mass be , the actual container mass be , and the measured gross value be , where is measurement error. Then
Repeating weighings can assess variation in , but it does not by itself remove an incorrectly chosen . A useful check therefore weighs representative empty containers as well as repeating loaded measurements. Report the stored tare and what it represents along with the result. This makes the physical assumptions behind a calculated net value visible rather than treating a precise-looking display as evidence that every container has the nominal tare mass.
A grain (unit) is a unit of mass equal to exactly , or . Thus a recorded mass of ten grains converts to . The abbreviation is ; it must be distinguished from , the symbol for a gram.[ref]
A grain (unit) measures mass, whereas a minim measures volume. Converting a volume to a mass additionally requires the material's density, so these units cannot be substituted for one another. The exact conversion is useful when interpreting an older measurement without treating the mass of an individual seed as a physical standard.
The dimensionless ratio of two specified masses.
Passive gravitational mass is the coefficient in for an imposed Newtonian gravitational field. Active gravitational mass instead measures a body's contribution to the source of that field in Newton's law of universal gravitation. Universality of the ratio of passive gravitational mass to inertial mass is the Newtonian content of the weak equivalence principle. In general relativity, the source is the full stress-energy tensor, rather than a single scalar gravitational mass.
In Newtonian mechanics, inertial mass is the coefficient in , measuring a body's response to a net force. The weak equivalence principle makes its ratio to passive gravitational mass universal; choosing compatible units then sets the two equal.
A description of how mass is assigned to positions, expressed for example by point masses, a mass density, or a measure. Writing allows centre of mass and moment of inertia formulas to cover both discrete and continuous cases.
A planar lamina is an ideal mass distribution confined to a plane, with surface mass density and infinitesimal mass . Its moment of inertia about an axis is the integral of squared perpendicular distance against this mass element. Three mutually perpendicular axes through one point, with two in the lamina's plane, obey the perpendicular axis theorem even when the density is nonuniform.
A point mass idealizes a localized body's mass density as , using the Dirac delta function. Its second mass moment tensor is . The approximation ignores its internal size and structure.

Ancestors (4)

  1. Classical mechanics
  2. Branches of physics
  3. Physics
  4. Home

Discussion (0) New discussion

There are no discussions about this article yet.

Articles by others on the same topic (2)

Mass is a measure of the amount of matter in an object or substance. It is a fundamental property in physics and is typically measured in units such as grams (g) or kilograms (kg). Mass is a scalar quantity, meaning it has magnitude but no direction.