An emulsion range measurement follows a stopping charged particle through the coating to estimate its complete particle range. A projected length on one image can underestimate the distance travelled. In an original geometry example, a straight segment with projected length and corrected depth change has length
Using the projection alone would underestimate this length by . A bent track requires a sum over reconstructed segments. These are stipulated coordinates, not measurements of a historical track.
Suppose photographic processing contracts the coating only in depth, with shrinkage ratio . Then an observed depth difference corresponds to . For , an observed becomes the used above. This correction assumes uniform contraction and unchanged lateral dimensions; it cannot repair a track that leaves the coating before stopping.
A simple continuous-loss model connects particle range to kinetic energy through stopping power :
This describes the mean trend for a specified particle and material. Fluctuating energy loss produces a spread of stopping distances, called range straggling. An exit point supplies only a lower bound on particle range. Consequently, a narrow distribution from fully contained tracks and one assembled by treating exits as stops answer different questions.
Range straggling is the event-to-event spread in particle range for otherwise similar incident particles, caused by fluctuations in their energy loss and transport through matter. It must be distinguished from measurement uncertainty and from the incomplete recording of particles that escape.