For an ideal air-gap Fabry–Pérot etalon at normal incidence, the free spectral range is and the peak full width at half maximum is . To separate a pair of lines spaced by by at least peak widths, require . Putting both lines inside one unambiguous free spectral range additionally requires , so . In terms of their vacuum wavelengths, .
The strict order condition needs a margin if tails from adjacent periodic peaks are to be negligible. If every neighbouring peak in a scanned two-line periodic spectrum must be separated by widths, the stronger condition is . Ordinary resolving power alone does not prevent ambiguous repeated orders. A fixed etalon's transmission as a function of wavelength is a periodic-in-frequency filter; it is not automatically a plot of the incident source's spectral lines.