Frustrated total internal reflection occurs when a nearby second high-index dielectric couples to the evanescent field in total internal reflection, allowing power to cross a finite low-index gap. The extra boundary changes the dielectric-interface boundary conditions; the gap field need not be a single decaying evanescent wave. Consequently, the zero normal Poynting vector calculation for two infinite half-spaces does not forbid transmission in this three-medium geometry.
Harvard’s actual demonstration uses two right-angle glass prisms, a helium-neon laser, a small clamp and two perpendicular screens as detectors. The contact faces are cleaned and placed opposite each other, with the clamp protecting the corners. Increasing pressure narrows the intervening air film; the observed beam routing changes gradually from total internal reflection toward onward transmission. The broad-gap reflecting configuration supplies the comparison for the narrow-gap transmitting configuration. This is a qualitative readout: the page explicitly says the gap is not measured.[ref]
Frustrated Total Internal Reflection by Harvard Natural Sciences Lecture Demonstrations. How it works and Setting it up: two prisms, HeNe laser, perpendicular screens, pressure adjustment and unmeasured gap
The inference is that the lower-index region can mediate electromagnetic energy transfer when another boundary is nearby. The demonstration does not determine a numerical evanescent penetration depth, resolve gap uniformity, or establish a three-layer transmission coefficient. For the constructed example, identifies the scale over which the isolated-interface field remains appreciable; substituting for a gap transmission fraction would omit the changed boundary fields and their interference. A quantitative gap calculation must solve the full Maxwell equations with both boundaries.
Articles by others on the same topic
There are currently no matching articles.