NCERT's teaching experiment uses a moving-coil galvanometer, a 0–6 V supply, a 0–10 kΩ series electrical resistance box , a 0–200 Ω parallel electrical resistance box , two switches and a voltmeter. With the parallel path open, close the supply switch and record the pointer deflection. Keep fixed, close the parallel path, and adjust until the deflection halves. The guide requests repeated settings, clean tight contacts and constant supply electromotive force; it introduces high before energizing to protect the winding. [ref]
Write the winding electrical resistance as , the supply electromotive force as , and assume negligible supply internal electrical resistance. Ohm's law gives the two winding electric currents
If proportional deflection gives , solving yields , requiring . The shortcut requires ; closing the parallel path generally changes the total supply electric current. For chosen values and , the exact result is , rather than . The manual gives this exact relation and asks how finite supply internal electrical resistance affects it. [ref]
As an additional calibration control, record the supply-off zero, apply several small positive and negative electric currents, and recheck zero after each sequence. With known, calculate each electric current from the measured supply electric potential difference and the total series electrical resistance; plot settled deflection against that electric current. Equal-magnitude reversed readings should lie equally far from a stable zero. A fitted relation separates zero offset from galvanometer current sensitivity. The manual's “figure of merit” is electric current per scale division, not the mechanical torsional spring constant used above. These reversal and zero checks extend the documented procedure; they are proposed controls, not reported measurements.
The galvanometer current sensitivity is the change in settled deflection angle per change in electric current. In the linear model its derivative is constant, . The illustrative design has , or per . A chosen full-scale angle corresponds to ; a straight-line extrapolation beyond that range does not establish real instrument behavior.
Figure 1.
Illustrative moving-coil calibration, current reversal and finite zero resolution
. Calculated deflection for the original design, with selected calibration points and a close view of zero. The shaded band is a stipulated readout tolerance, corresponding to about ; it is not measured noise. Values and points are illustrative model predictions, not observations from a real instrument. Source. Details.
Finite sensitivity and finite readable angle set different limits. Under the stipulated tolerance, a reading indistinguishable from zero means only if the zero is stable and the model applies. More turns can increase galvanometer current sensitivity while also increasing winding electrical resistance; the response to an applied electric potential difference depends on both. Friction, zero drift, departures from the radial magnetic field, and spring nonlinearity can spoil the calibration. Damping sets how long one must wait for a settled reading. A rapidly reversing electric current can produce little mean pointer deflection even when its instantaneous magnitude is large.