MINOS 2026-10-25
A long-baseline neutrino oscillation experiment using a Fermilab beam, near and far detectors, and magnetized iron/scintillator sampling calorimeters. A charged current muon neutrino event gives a negative muon and a hadronic shower; their reconstructed energies estimate the incident neutrino energy.
Strike a target with high-energy protons, collect negative pions and kaons with magnetic horns, and let them decay in a long evacuated decay tunnel: and . Absorb residual hadrons and range out muons in shielding. Focusing selects the negative parent sign and therefore enriches muon antineutrinos; other parent decays leave a finite contamination. Monitor the parent flux and use a near detector to constrain the unoscillated spectrum.
A massive segmented calorimeter supplies interaction probability and measures the hadronic shower. Alternate dense absorber plates with scintillation counters or tracking planes, and magnetize the iron or add a downstream magnetic muon detector. The signal is a positive muon plus a hadronic shower; the sign rejects much of the muon neutrino contamination. For a contained muon, its range gives energy; for a penetrating track, curvature gives . Multiple measurements and a field map determine the fitted momentum and sign. Summed calibrated shower response estimates the struck quark's visible hadronization energy, not the energy of a free observable quark. Correct for invisible nuclear losses, noncompensating response, leakage and acceptance. Neglecting target recoil corrections, and .
The Fermilab primary proton beam strikes a target, producing secondary pions and kaons. Horn focusing selects positive parents; their decays and produce a predominantly muon neutrino beam. A decay tunnel permits decay before the remaining charged secondaries encounter an absorber. A near detector constrains the flux and interaction spectrum, while the distant MINOS detector measures its change.
The alternating scintillation counters and magnetized iron give a sampling calorimeter and a magnetic tracking volume. A charged current event has a long negative muon track and a localized hadronic shower. Estimate by range if contained or magnetic curvature if exiting, and by the calibrated scintillator pulse-height sum. Reconstruct , with corrections for nuclear binding, invisible energy and detector response. The muon charge separates most wrong-sign muon antineutrino events; short showers without the track are primarily neutral current candidates. The source's baseline is used in the calculations below.
TODO: a numerical estimate from the missing MINOS spectrum cannot be supplied. On source page 7 the graph is absent: PDF Form /Im3 invokes undefined image /Im1 with no image resources, and the archived bundle has the same defect. In particular, no measured minimum energy survives. For maximal mixing angle, the first minimum of muon neutrino survival obeys
A restored spectrum or fitted data are needed to choose . This is a relation for the survival minimum; a minimum in the raw event spectrum also depends on flux, cross section and smearing. For context only, accelerator and atmospheric results put the splitting at a few , versus the solar splitting about , roughly thirty times smaller. This known scale is not a reconstruction of the absent graph. [ref]
Finite event statistics, hadronic shower energy resolution, the muon scale, near-to-far flux extrapolation, interaction and nuclear modeling, backgrounds and detector calibration limit the precision; the baseline itself is comparatively well known. In a two-flavour vacuum fit the sign of is inaccessible. Evidence for dominant includes the zenith-angle-dependent atmospheric deficit in Super-Kamiokande, approximately preserved active neutral current rates, small electron-flavour appearance at this scale, atmospheric tau appearance and direct tau appearance in OPERA. The latter had already reported four candidates and evidence in 2014; a later five-candidate discovery result is not needed for this June 2015 answer. [ref] These tests constrain a dominant sterile conversion as well as conversion into electron neutrinos.
A general-purpose collider detector surrounds the interaction region with complementary layers. The layout makes the measured signals useful together: tracks establish charged trajectories, calorimeters sum deposited energy, and outer detectors identify penetrating muons.
Near-hermetic coverage permits a missing transverse momentum estimate from the calibrated vector sum, signaling neutrinos or other invisible particles but also sensitive to detector failures and escaping jets. At a hadron collider the initial parton longitudinal momenta are unknown, so missing longitudinal energy cannot be inferred in the same way; an collider supplies stronger initial-state constraints. Every subsystem needs alignment, calibration and independent control samples for reliable combined reconstruction.