Aleš Fajgelj is an analytical chemistry researcher whose work includes metrological traceability, recovery information and laboratory quality assurance. The 2011 IUPAC traceability report identifies his affiliation with the International Atomic Energy Agency's Department of Nuclear Sciences and Applications.[ref]
Metrological traceability of measurement results in chemistry: Concepts and implementation by Paul De Bièvre and others. Publisher byline and affiliation 3.
With Paul De Bièvre, René Dybkær and D. Brynn Hibbert, Aleš Fajgelj prepared recommendations intended to give chemical measurement a consistent account of the creation, meaning and role of metrological traceability. He also coauthored the 1999 recovery-information report, connecting the interpretation of laboratory results with the handling of losses during preparation.[ref]
Metrological traceability of measurement results in chemistry: Concepts and implementation by Paul De Bièvre and others. Abstract.
[ref]An original example illustrates the distinction between documenting a reference and validating a process. Suppose a standard solution's assigned concentration is connected to a specified reference through documented measurements. If an unknown loses 20% of its analyte during preparation while the standards do not, that documented standard alone does not justify treating the unknown's preparation loss as zero. The measurement model must represent the relevant stages and their measurement uncertainty.
Likewise, agreement in an interlaboratory comparison supplies evidence about the compared results, but does not by itself write the missing chain of reference relationships. The value of Aleš Fajgelj's standards work lies in making those distinctions explicit enough for laboratories to communicate what a result means.
Michael Thompson 2026-11-05
Michael Thompson is an analytical chemistry researcher named at Birkbeck College in the 1999 international guidelines on using recovery information in analytical measurement. The paper addresses how losses during sample preparation affect reported results, their comparability and their measurement uncertainty. Its authorship and affiliation identify this contribution without conflating other scientists of the same name.[ref]
Harmonised guidelines for the use of recovery information in analytical measurement by Michael Thompson and others. full byline and affiliation; Introduction
A central distinction is between correcting an estimated loss and treating the correction as perfectly known. In a specified recovery correction model,where is the uncorrected result and the estimated fractional recovery. The guide treats the determination's uncertainty and the recovery estimate's uncertainty separately. For independent inputs, first-order propagation givesThis states an uncertainty calculation, not a rule that every analytical measurand must be defined identically.[ref]
Harmonised guidelines for the use of recovery information in analytical measurement by Michael Thompson and others. §6, Uncertainty in Reporting Recovery; Appendix, Recovery and Uncertainty
For an original example, stipulate with standard uncertainty and with . The corrected result is andTreating recovery as exact would give only . The added uncertainty describes limited knowledge of the correction; omitting it does not make the physical measurement more reliable. Correlated estimates require the appropriate covariance term instead of this independent-input formula.
The experiment used to estimate recovery also matters. An added, readily dissolved analyte may not behave like native analyte strongly bound within the sample matrix. The guidelines discuss this limitation of surrogate recovery studies and the need to consider matrix variation.[ref]
Harmonised guidelines for the use of recovery information in analytical measurement by Michael Thompson and others. §§3.2–3.3, native/surrogate behavior and matrix mismatch; §5.1, representative recovery studies
A useful validation therefore specifies what material was added, when it was added, which matrices were represented and whether the procedure had time to equilibrate.Thompson and his collaborators' reporting recommendations call for identifying whether results are recovery corrected and how the correction was obtained. This makes two laboratories' numbers interpretable: a corrected estimate of total analyte and a reproducible result defined by a particular extraction procedure can otherwise look like measurements of the same quantity when they are not.[ref]
Harmonised guidelines for the use of recovery information in analytical measurement by Michael Thompson and others. Recommendations, reporting correction status, magnitude and derivation
Paul Willetts (analytical chemist) 2026-11-05
Paul Willetts is an analytical chemistry researcher associated with studies of laboratory performance and analytical sampling. The recovery-information report lists him at the MAFF Food Science Laboratory in Norwich, establishing the identity independently of unrelated authors with the same name.[ref]
Harmonised guidelines for the use of recovery information in analytical measurement by Michael Thompson and others. Eurachem-hosted text, title page and affiliation 4.
With Michael Thompson, Sharron Anderson, Paul Brereton and Roger Wood, Paul Willetts studied collaborative sampling of wheat and green coffee from bulk lots. Multiple samplers allowed the study to distinguish variation under different sampling conditions. Between-sampler variation contributed significantly for two wheat analytes; the coffee results showed significant sampling-repeatability variation without a detected significant sampling-reproducibility contribution.[ref]
Collaborative trials of the sampling of two foodstuffs, wheat and green coffee by Michael Thompson and others. Abstract, sampling design and contrasting results.
The measurement begins before material reaches the instrument. For an original illustration, two perfectly repeatable preparations might contain and because the collected portions differ. Repeating each instrument reading a hundred times would not make those portions identical. Measurement repeatability within a portion and measurement reproducibility across the relevant procedures therefore cannot be inferred from the same replication design.
Paul Willetts also coauthored the recovery-information guidance. Together these contributions emphasize that sample matrix, material selection, preparation loss and stated measurement uncertainty belong in the interpretation of an analytical result. They cannot all be assessed by repeatedly reading a single prepared solution.
Recovery correction 2026-11-05
A recovery correction adjusts an analytical result to account for an estimated loss of analyte during a specified preparation stage. If the recovered amount follows , with original amount and extraction recovery , the corrected estimate is . Its validity depends on whether the recovery estimate applies to that analyte, sample matrix and procedure.
For an original example, and give . The calculation estimates the amount before loss; it does not restore molecules to the sample. It also does not separately correct a mass spectrometry matrix effect unless that effect has been included consistently in the measurement model.
Recovery-correction uncertainty follows from the quotient, not just from the measured amount. First-order propagation of uncertainty givesIf the two inputs are independent, the covariance term vanishes. With stipulated standard uncertainties and , the two variance contributions are and , giving . The recovery estimate dominates this example; dividing by recovery has not created extra precision.
A recovery inferred from a spiked preparation need not reproduce the behavior of analyte originally embedded in a sample. Likewise, applying a single recovery at every concentration assumes a common model. Near-zero or very uncertain recovery can make quotient inference unreliable beyond the linear uncertainty approximation.
Reporting whether a correction was applied, its size and how it was derived makes results comparable. These reporting provisions appear in the harmonised recovery guidelines and their Codex adoption text.[ref]
Harmonised guidelines for the use of recovery information in analytical measurement by Michael Thompson and others. Recommendation1 reporting provisions, reproduced at the linked FAO Codex text.
Roger Wood (analytical chemist) 2026-11-05
Roger Wood is an analytical chemistry researcher whose work concerns the reliability and comparability of laboratory results. The 1999 recovery-information report identifies him with the MAFF Food Science Laboratory in Norwich and lists him among its five authors.[ref]
Harmonised guidelines for the use of recovery information in analytical measurement by Michael Thompson and others. Eurachem-hosted text, title page and affiliation 4.
The report addresses a practical difficulty: two laboratories can obtain different answers from the same material if one applies a recovery correction and the other reports the recovered amount. It develops a framework for estimating, applying and reporting recovery information rather than treating a percentage as a context-free property of a method.[ref]
Harmonised guidelines for the use of recovery information in analytical measurement by Michael Thompson and others. Introduction and Recommendations.
Roger Wood also supported the launch of the RSC Analytical Methods Committee's Technical Brief series while chairing that committee. The RSC's own account credits Michael Thompson as the instigator and Roger Wood as a strong supporter; the first brief appeared in 2000.[ref]
The RSC Analytical Methods Committee Reaches a Milestone in Technical Brief Publication. Technical Briefs section.
An original numerical illustration shows why laboratory agreement needs interpretation. If one laboratory recovers from material containing and reports 8, while another applies an appropriate recovery estimate 0.8 and reports 10, their discrepancy can arise from reporting conventions without a difference in recovered amount. Conversely, laboratories sharing an unsuitable correction can agree and remain biased. Interlaboratory comparison and clear reporting answer complementary questions about a measurement system.
Spike equilibration 2026-11-05
Spike equilibration is the process by which added analyte comes to share the chemical forms or physical environments relevant to recovery of the native analyte. Mixing a solution uniformly is not sufficient if native material is bound, trapped or otherwise inaccessible to the added material. The spike-recovery estimate is representative only to the extent that the two undergo comparable processing.
IUPAC's recovery guidance makes this equivalence a condition for using an added surrogate to correct native recovery. It notes that even an isotopically modified analyte can fail to equilibrate with native material bound to the sample matrix.[ref]
Harmonised guidelines for the use of recovery information in analytical measurement by Michael Thompson and others. Eurachem-hosted text, §§3.2–3.2.2, equivalence, isotope dilution and spiking.
An original two-environment model describes a fast-extractable fraction approaching :Let the fresh spike start entirely accessible, , while native material has accessible fraction . With stipulated spike equilibration time , a 15-minute wait leaves , not 0.20. If extraction measures only the accessible material, correcting a native recovered amount 20 by the spike's apparent recovery 0.240 gives approximately 83.4, below the true 100 amount units. The mismatch persists despite a high initial spike recovery.
A useful test varies the waiting time before extraction while keeping preparation and added analyte amount fixed. Compare the behavior of the spike with independent native-material or reference material evidence where available. A stable time series supports constancy over that window, but cannot prove that an inaccessible native compartment has been sampled.
More vigorous processing may change chemical forms or destroy the analyte; longer waiting alone does not guarantee equivalence. State addition timing, equilibration conditions and the extraction stage to which the measured extraction recovery applies. These choices are part of the measurement model, rather than details that can be recovered from the final percentage alone.
Spike equilibration time 2026-11-05
A spike equilibration time characterizes how rapidly added analyte approaches the distribution relevant to native-material recovery. A model's time constant differs from the waiting time needed to meet a specified analytical tolerance. Neither is a universal property independent of sample matrix, chemical form and preparation conditions.
For the illustrative first-order spike equilibration modelthe deviation from equilibrium falls to of its initial value after . Suppose acceptance requires , with . If the initial mismatch exceeds the tolerance, solving givesFor original stipulated values , , and , the waiting time is at least . After three time constants, the residual deviation is only5% of its initial value but still approximately20% of the equilibrium accessible fraction. The denominator in the acceptance criterion matters.
At known equilibrium value, two positive deviations at estimateIf is fitted from the same observations, its uncertainty and covariance must also be considered. A time series with few late observations can make the plateau and time constant difficult to distinguish.
Experimentally, prepare matched portions with different waiting times before the same extraction. IUPAC warns that added and native material may fail to reach equivalent states, especially when native analyte is bound to the sample matrix.[ref]
Harmonised guidelines for the use of recovery information in analytical measurement by Michael Thompson and others. Eurachem-hosted §§3.2.1–3.2.2, effective equilibrium and bound native analyte.
A stable signal alone cannot distinguish complete equilibration from an inaccessible pool or a competing degradation process. State the observed quantity, waiting conditions and acceptance criterion when reporting an equilibration time. Spike-recovery estimate 2026-11-05
A spike-recovery estimate compares the measured increment after adding a known analyte amount to a sample with the amount added. It tests the response to the added material under the stated preparation and measurement calibration; it does not automatically measure recovery of analyte originally bound or embedded in the sample matrix.
If matched aliquots give inferred amounts and after accounting for dilution, and was added, the incremental apparent recovery isAn original dilution example starts with a aliquot whose unspiked result is . Add containing of analyte; the added amount is . If the spiked solution measures , thenSubtracting the two concentrations without accounting for the changed volume would give a different answer. Alternatively, bring the spiked and unspiked aliquots to the same final volume before comparing them.
The spike's point of addition defines what is tested. Added before extraction, it experiences preparation loss and matrix-dependent response; added afterward, it cannot establish the earlier extraction recovery. Spike equilibration also matters: freshly added dissolved analyte may not access the same binding sites or compartments as native material. IUPAC's recovery guidance distinguishes recovery of native and added surrogate material and their possible differences.[ref]
Harmonised guidelines for the use of recovery information in analytical measurement by Michael Thompson and others. Eurachem-hosted text, §§3.2–3.2.2, native/surrogate recovery and spiking.
Use multiple spike levels and matched unspiked aliquots to look for concentration-dependent response. An incremental result near 100% can coexist with a constant interference in both aliquots, because subtraction removes that shared offset. The result therefore supports a particular recovery comparison, rather than proving every source of analytical bias absent.
Stephen L. R. Ellison 2026-11-05
Steven L. R. Ellison is the name printed for an analytical chemistry coauthor of the recovery-information report, with an affiliation at the Laboratory of the Government Chemist in Teddington. Eurachem's later organizer biography identifies the same report among the works of Stephen L. R. Ellison, an LGC Fellow specializing in analytical statistics and measurement uncertainty.[ref]
Harmonised guidelines for the use of recovery information in analytical measurement by Michael Thompson and others. Eurachem-hosted title page, printed Steven L R Ellison and affiliation 2.
[ref]Stephen L. R. Ellison biography in the 2017 Eurachem workshop abstracts. Printed p.94, named biography and explicit report-coauthorship link.
The Eurachem biography also identifies him as a principal author of Quantifying Uncertainty in Analytical Measurement and a coauthor of method-validation and laboratory-proficiency-testing guidance. This work develops the statistical interpretation needed to compare analytical results under stated conditions.[ref]
Stephen L. R. Ellison biography in the 2017 Eurachem workshop abstracts. Printed p.94, scientific contributions.
For an original illustration, two independent uncertainty contributions of and combine to in quadrature. If their correlation coefficient is 0.5 and both enter the model with positive sensitivity, the combined standard uncertainty is insteadThe model determines which inputs contribute and whether covariance matters. Listing more decimal places does not resolve an omitted source of uncertainty. This calculation illustrates the subject of the guidance; it is not experimental data attributed to Ellison.