In the vertical equations, denotes dynamic viscosity, while is the mean molecular weight in units of the proton mass . The symbol denotes the Boltzmann constant. For the intended hydrostatic equilibrium calculation, put with , , and set . Dividing the hydrostatic equation by and integrating from the symmetric midplane gives
The specific enthalpy vanishes at the free surface. Hence the polytropic vertical structure in stellar gravity is
On , the ideal gas relation gives and ; the vacuum extension sets outside. The formula needs for a finite positive semi-thickness and assumes the harmonic vertical gravity remains valid through this height.
There is a genuine inconsistency if all four printed structure equations are imposed literally with and finite positive opacity: radiative diffusion then requires , whereas the polytropic temperature above has a nonzero gradient away from the midplane. The intended result is valid for the hydrostatic polytropic equation of state with the radiative closure replaced or neglected, for example an adiabatic opaque limit. It is not an exact simultaneous solution of the stated finite-opacity radiative system. With that radiative system and a nonvacuum ideal gas, instead gives an isothermal solution
which has no finite free surface. For , constant and constant would force constant density, contradicting hydrostatic balance on a nontrivial vertical interval. This is the zero-radiative-flux obstruction for a polytropic ideal gas.
Use a gas-pressure-supported, optically thick alpha disk, with and positive parameters. Here is the Stefan–Boltzmann constant in the Stefan–Boltzmann law, and and below are heating and cooling flux estimates per disk face. Hydrostatic equilibrium and the ideal gas relation give , while . Integrating viscous heating over one semi-thickness and estimating radiative diffusion give
Here the stipulated negative hydrogen ion opacity exponent is , which is a local approximation distinct from other empirical opacity fits. Substituting and equating heating and cooling gives
Dropping numerical constants of order one is essential here. This is the negative-hydrogen-opacity alpha-disk thickness scaling. Its angular thickness estimate is
For a central mass , Keplerian rotation gives , so . The isothermal sound speed is
An adiabatic sound speed differs by the constant factor if the adiabatic index is fixed. For , constant , and fixed composition, the disk aspect ratio grows as , so there is disk flaring when ; . The problem supplies no numerical parameters or specified , so no unique numerical or unconditional radial power can be inferred.
If the additional standard closure of a constant inward accretion rate well outside a zero-torque edge is intended, and imply . Eliminating it gives at fixed , hence and . These stronger powers use that extra steady-flow assumption. All these local scalings cease to apply if the thin disk or the stated opacity regime fails.
Assume the vertical dynamical timescale of a disk is shorter than the thermal timescale of an accretion disk, which is itself shorter than the viscous timescale. This ordering is controlled in a thin disk with : , and . Therefore compare heating and cooling at fixed surface density of a disk, radius, and composition. Vertical hydrostatic equilibrium adjusts on the vertical dynamical timescale of a disk, giving and . Consequently the stipulated negative hydrogen ion opacity varies as . The rates per disk face then scale as
Thus heating increases while cooling decreases after a positive temperature perturbation. At equilibrium , a small change gives , which drives the perturbation further from equilibrium for positive effective heat capacity. A negative temperature perturbation likewise increases the net cooling. This proves thermal instability from negative hydrogen ion opacity within the local closure; it is the temperature-slope test of thermal stability of an accretion disk. Holding volume density rather than surface density of a disk fixed would give a different cooling exponent, but still the same qualitative instability; the fixed-column comparison is the relevant thin-disk thermal test.