For the fundamental alone, the Nyquist–Shannon sampling theorem places the limiting sampling rate at twice that frequency:Use a rate strictly above this boundary for a sinusoid of unknown phase: exactly two samples per cycle can, for a particular phase, all fall at zero. If higher Fourier harmonics are retained, the sampling rate must instead exceed twice the highest retained frequency, or those components must be removed to prevent aliasing.
For a straightforward discrete Fourier transform estimate, Fourier frequency resolution obeys . Resolving therefore suggestsAt the limiting sampling rate this is about samples. These are the usual sampling and spectral-resolution estimates. The value is not a universal lower bound on single-tone frequency estimation: fitting a sinusoidal model with sufficiently low noise can estimate its frequency more precisely than the spacing of discrete Fourier transform bins. The question gives no noise level or estimator, so a sharper universal minimum time cannot be deduced.