At an interface with unit normal pointing from medium 1 to medium 2, the magnetic boundary conditions are
The first follows from a pillbox applied to . The tangential magnetic field jump from a free surface current follows from a shrinking rectangular Ampère loop; is the free surface current. With no free sheet current, normal and tangential are continuous. In linear isotropic media , so neither all components of nor all components of generally remain continuous.
For magnetic field-line refraction at a permeability interface, with angles measured from the normal, these conditions give . They determine the bending of magnetic flux at a material interface. In a slender core electromagnet, flux continuity and Ampère's law lead to the magnetic-circuit estimate
An air gap can dominate the reluctance even when the iron core has high magnetic permeability. Boundary conditions also determine demagnetizing fields; fringing, saturation and hysteresis limit the simple linear circuit model. A high-magnetic permeability material redirects flux, whereas a perfect-conductor boundary is a different physical assumption.[ref]