Assume steady fully developed laminar flow of a Newtonian fluid in a long circular tube, with no slip at a rigid wall. The Hagen-Poiseuille equation gives the volume flow rate
where is the lumen radius, the tube length, the dynamic viscosity and the pressure drop. If , and remain fixed, then
Thus doubling the flow requires
This estimate neglects pulsation, arterial compliance, entrance losses, the detailed shape of a stenosis and changes in the rest of the circulatory resistance. It treats blood as a homogeneous Newtonian fluid and assumes that enlarging the artery does not change its applied pressure drop. These assumptions supply the intended fourth-power scaling; an actual circulation need not keep that pressure drop fixed.